Technical Data; Warranty Statement - Pressure Tech LF-540 Series Operating And Service Manual

Table of Contents

Advertisement

7. Technical Data

Fluid Media:
Max Inlet Pressure*:
Outlet Pressure Range:
Operating Temperature:
Materials:
Flow Capacity (Cv):
Leakage:
*Max Inlet Pressure determined by seat material and Cv of regulator.

8. Warranty Statement

Pressure Tech Ltd guarantee all products correspond with their specification at the time of
delivery and, with exception to wear and tear, wilful damage, negligence, and abnormal
working conditions, will be free from defects for a period of 12 months from date of
delivery.
9
All gases and liquids compatible with materials of
construction
550 bar (8000 Psi)
0-414 bar (6000 Psi)
-20°C to +80°C (Nominal)
Body and Trim: 316 SS
Seat: PCTFE / PEEK® / Ceramic
0.1 / 0.2 / 0.3
Gas: Bubble tight
Liquid: Zero drops of water at max inlet