2. Pair all repeaters to the receiver:
– Repeaters A, B and C all need to be paired to the receiver
individually
3. Only pair sensors into the repeater(s) closest:
– Sensor D is paired to repeater C since it is closest to repeater C
– Sensor D is not paired to repeater A and B
4. Pair all sensors, that are paired to a repeater, to the receiver:
– Sensor D is paired to the receiver
N N o o t t e e ! ! It is strongly suggested to keep a distance between each repeater
and/or receiver to avoid cross signalling.
If a particular sensor is within an acceptable range for the receiver to re-
ceive its transmission signal, it is strongly recommended to pair the sensor
to the receiver directly instead of to the repeater.
Example 1
D
B
C
RCW-...
A
Figure 2 Receiver RCW-M32, repeaters A, B and C, with RF coverage, and sensor D
In this example the sensor is located between the RF coverge of repeater
B and C. Users can choose to pair it to repeater B only, pair it to repeater
C only, or pair it to both repeater B and C. It is recommended to pair the
sensor to repeater B only to reduce signal traffic.
N N o o t t e e ! ! In this example, repeater C is also paired to repeater A or B or both
so the signals from repeater C can be relayed to the receiver through re-
peater A or B, or either.
Example 2
B
C
D
RCW-...
A
Figure 3 Receiver RCW-M32, repeaters A, B and C, with RF coverage, and sensor D
In this example the sensor is located between the RF coverge of repeater
A,B and C. Users can choose to pair it to repeater A only, or pair it to
repeater A, B and C. Nevertheless it is recommended to pair the sensor to
repeater A only or repeater B only, to reduce signal traffic.
N N o o t t e e ! ! In this example, repeater C is also paired to repeater A or B or both
so the signals from repeater C can be relayed to the receiver through re-
peater A or B.
This product carries the CE-mark. More information is available at
www.regincontrols.com.
Contact
AB Regin, Box 116, 428 22 Kållered, Sweden
Tel: +46 31 720 02 00, Fax: +46 31 720 02 50
www.regincontrols.com, info@regincontrols.com
SE
INSTRUKTION
RPW
O O b b s s e e r r v v e e r r a a ! ! Läs och förstå instruktionen innan du använder produkten.
O O b b s s e e r r v v e e r r a a ! ! Se till att installationen uppfyller lokala
säkerhetsbestämmelser.
V V a a r r n n i i n n g g ! ! Innan installation eller underhåll måste matningsspänningen först
kopplas från för att undvika potentiellt dödliga elstötar! Installation eller
underhåll av denna enhet ska endast utföras av kvalificerad personal. Till-
verkaren är inte ansvarig för eventuella skador som orsakas av felaktig in-
stallation och/eller inaktivering eller borttagning av säkerhetsanordningar.
RPW
Funktion
Repeatern är utformad för att öka effektiviteten och mångsidigheten i
det trådlösa systemet. Den gör ditt system mer kraftfullt genom att öka
det största möjliga avståndet mellan mottagaren och givaren eller
detektorn.

Tekniska data

Matningsspänning
230 V ~ (100...240 V ~ 50/60 Hz)
Matningsspänning adapter 12 V DC, 1 A
Effektförbrukning
0,5 A
Batteribackup
ja
Frekvens
868 MHz
Skyddsklass
IP30
Montering
Vägg
Material, kapsling
Polykarbonat (PC)
Färg, kapsling
RAL9010
Dimensioner
185 x 130 x 30 mm

Installation

1 2
3 4
10
1
Lysdiod för spänning
På: Spänningssatt med en adapter eller internt
(grön)
laddningsbart batteri
Blinkning: Interna laddningsbara batteriet har
låg spänning
2
Lysdiod för inställning-
På: Repetern är i driftläget parkoppling (RCW-
ar (gul)
M32) eller rensa
Blinkning (1 blinkning varje sekund): repeatern
är i driftläget gångtest
Långsam blinkning (1 blinkning varannan se-
kund): repeatern är i driftläget parkoppling
5
6
7
8
9
11
3 (11)

Advertisement