Toshiba Carrier RAV-SP181BT-UL Installation Manual page 19

Air conditioner (split type)
Hide thumbs Also See for Carrier RAV-SP181BT-UL:
Table of Contents

Advertisement

 Manual address setup
procedure (Procedure
example 1)
While the operation stops, change the setup.
(Be sure to stop the operation of the unit.)
7
3
3
-2,
-1,
4
4
-2,
-1,
5
5
-1,
-2
7
3
-3,
4
-3,
5
-3,
1
2,6
1
Procedure
Push simultaneously
+
+
buttons for 4 seconds or
more. After a while, the display part flashes as shown below.
Check the displayed CODE No. is [10].
• When the CODE No. is other than [10], push
erase the display and repeat procedure from the first step.
(After pushing
button, operation of the remote control
is not accepted for approx. 1 minute.)
(For a group control, No. of the firstly displayed indoor unit
becomes the header unit.)
(* Display changes according to
the model No. of indoor unit.)
2
Procedure
Every pushing
button, the indoor UNIT No. in the
group control is displayed in order. Select the indoor unit of
which setup is changed.
In this time, the position of the indoor unit of which setup is
changed can be confirmed because fan of the selected
indoor unit operate.
35-EN
3
Procedure
1. Using temp. setup
/
buttons, specify CODE
No. [12].
(CODE No. [12]: Line address)
2. Using timer time
/
buttons, change the line
address from [3] to [2].
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
4
Procedure
1. Using temp. setup
/
buttons, specify CODE
No. [13].
(CODE No. [13]: Indoor address)
button to
2. Using timer time
/
buttons, change the indoor
address from [3] to [2].
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
5
Procedure
1. Using temp. setup
/
buttons, specify CODE
No. [14].
(CODE No. [14]: Group address)
2. Using timer time
/
buttons, change the SET
DATA from [0001] to [0002].
(SET DATA [Header unit: 0001] [Follower unit:
0002])
3. Push
button.
In this time, the setup finishes when the display
changes from flashing to lighting.
Indoor UNIT No. before setup change is displayed.
6
Procedure
If there is other indoor unit to be changed, repeat procedure
2
5
to
to change the setup.
When the above setup has finished, push
the indoor UNIT No. before change of setup, specify CODE
No. [12], [13], [14] in order with temp. setup
buttons, and then check the changed contents.
Address change check Before change:
[3-3-1] → After change: [2-2-2]
Pushing
button clears the contents of which setup was
changed.
2
(In this case, procedure from
is repeated.)
Indoor UNIT No. before setup change is displayed.
– 18 –
7
Procedure
After check of the changed contents, push
is determined.) When pushing
button, the display
disappears and the status becomes the usual stop status.
(When pushing
button the operation from the remote
control is not accepted for approx. 1 minute.)
* If the operation from the remote control is not accepted
even 1 minute or more passed after pushing
is considered that the address setup is incorrect.
In this case, the automatic address must be again set up.
Therefore repeat procedure of the setup change from the
1
Procedure
.
To recognize the position of the corresponding
indoor unit though the indoor UNIT No. is known
Check the position during operation stop.
(Be sure to stop operation of the set.)
to select
/
1,3
button. (Setup
button, it
1
2
EN
36-EN

Hide quick links: