BEFORE YOU START: See Safety information section for important precautions. Failure to follow these instructions can damage the unit and could also result in personal injury. Sealed Lead Acid
batteries have many hazards like high current, gases and acids. Please exercise caution. To avoid excess battery drain, turn the inverter OFF / disconnect after use.
Operation and Use
1
B
A
C
Remove the covers from the
1
terminals. Thread the power
input cable through the hole
in each cover and connect to
the inverter terminal (see below).
Replace covers.
Power Cable
Connection
Connecting the power cable
to the inverter terminal
must be done in this order.
WARNING: Reverse Input
Please ensure that the red (positive) ring terminal on your input cable connects to the positive (+)
terminal on both your battery and the inverter. The black (negative) ring terminal connects to the
negative (-) terminal on the battery and inverter.
1000 and 2000 Watt inverters: Reverse input will blow the fuse and disable the unit. Replace fuses
if this occurs.
3000 Watt inverters: Reverse input will permanently disable the unit and the inverter will need to
be replaced.

Safety Information

This section contains important safety information. Before using the inverter, READ ALL instructions and cautionary markings on or provided with the inverter, and all appropriate sections of this guide.
The inverter contains no user-serviceable parts.
WARNING: FIRE AND/OR CHEMICAL BURN HAZARD
Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS
INJURY
• Use and store the inverter in an indoor area away from direct sunlight, heat, moisture or conductive
contaminants.
• During use, allow a minimum of three inches of space around the inverter for optimal ventilation.
• When working with electrical equipment or lead acid batteries, have someone nearby in case of an
emergency.
• Study and follow all the battery manufacturer's specific precautions when installing, using and servicing
the battery connected to the inverter.
• Wear eye protection and gloves.
• Avoid touching your eyes while using this unit.
Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this occurs,
cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.
1000/2000/3000 Watt High Power Inverters
User Guide
2
2
Connect the ring terminals
to a 12 Volt battery.
Power
Bolt
Washer
Cable
1
2
3
3
3
Plug in your AC /
USB devices.
Inverter
Locking
Terminal
Washer
Washer
Nut
4
5
6
7
WARNING: Battery Voltage
Your inverter is designed to connect to 12 Volt batteries only. Using a higher voltage battery
will cause an over-voltage shutdown; using a lower-voltage will cause an under-voltage
shutdown (see Troubleshooting Guide).
• Use precautions by not smoking or having an open spark or fire near battery installations. Batteries
contain flammable materials.
• Keep unit away from moist or damp areas.
• Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit
which goes through the battery or another electrical tool that may create an explosion.
WARNING: Shock Hazard. Keep away from children!
Avoid moisture. Never expose unit to snow, water etc.
Unit provides 115 VAC, treat the output socket the same as regular wall AC sockets at home.
WARNING: Explosion hazard!
DO NOT use the inverter in the vicinity of flammable fumes or gases (such as propane tanks or large
engines).
AVOID covering the ventilation openings. Always operate unit in an open area.
WARNING: Medical equipment!
This product is NOT tested, designed nor intended to be used with life support systems or any other
medical device.
4
4
Turn the inverter ON.
The power button will turn
solid green and the LCD
screen will light up.
AC Outlet
Reset Button
3000 Watt inverters:
Each AC outlet features a manual reset
button which acts as a breaker in the
event of an overload or if the connected
item is short-circuited.
If these faults occur, the button will pop out and the outlet will
shut off. Unplug the connected item and press the button to
reset. The other outlets are not affected and will still operate.