Intended use
The pipe cleaning machines may only be used for cleaning pipes with a diameter of 32 mm to
100 mm.
The pipe cleaning machines are only designed for short-term operation and are therefore only
permitted for max. 15 min of continuous operation! This device may only be used as specified.
Control/inspection
Prior to commissioning the pipe cleaning device, a visual inspection must be carried out to de-
tect leaks, damage, loose, missing, or worn parts.
The pipe cleaning unit must be inspected immediately if it has been overloaded or subjected to
a strong impact. The control should be carried out by a specialist. An annual inspection of the
pipe cleaning device is recommended. Defective parts must be replaced immediately. If this is
not possible, the device must not be put into operation again.
Regularly apply lubricant to all moving parts. Regularly check the cleaner for rust, cracks and
corrosion. Clean the affected areas with an oily cloth.
If scrapping of the cleaner is necessary, please recycle it.
Maintain your tools with care. Keep the cutting tools sharp and clean for better and safer oper-
ation. Follow the instructions for lubrication and tool change. Periodically check the power cable
connection and, if damaged, have it replaced by a recognised specialist. Check the extension
cables regularly and replace them if they are damaged. Keep handles dry, clean and free of
grease and oil.
Technical specifications
Energy supply
Tube diameter (㎜)
Max. length (m)
Spring diameter (㎜)
Rotational speed (
r
min
Weight (㎏)
Working weight (㎏)
Input/output power (W)
Scope of delivery
Pipe cleaning machine
Guide hose (6 parts, total 13.8 m)
Drilling and cutting heads
Gloves
Assembly tool
Manual
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
230 V, 50 Hz
32–100
14
16
)
400
22
12
390/250