Installation and use of JYDM................23 Chassis environment monitoring in JYDM............. 26 Chassis cooling control in JYDM..............27 Chassis identification in NI MAX..............29 5.Using PXIe-2519 Chassis...................31 Using PXIe-2519 with JYTEK PXI/PXIe Peripheral Modules......31 Using PXIe-2519 with National Instruments PXI/PXIe Peripheral Modules.. 31...
Page 3
Figure 2 PXIe-2519 Gen2 Backplane Architecture..........2 Figure 3 Front View (PXIe-2519 Gen 3/Gen 2)............9 Figure 4 Left Side View (PXIe-2519 Gen 3/Gen 2) ..........9 Figure 5 Right Side View (PXIe-2519 Gen 3/Gen 2)..........10 Figure 6 Rear View (PXIe-2519 Gen 3/Gen 2)............10 Figure 7 Top View (PXIe-2519 Gen 3/Gen 2)............
Page 4
Table 2 Electrical Specification................6 Table 3 System Synchronization Clock..............7 Table 4 Continuous Current Capability..............7 Table 5 Environment....................8 Table 6 Acoustic Emissions..................8 Table 7 Backplane....................8 Table 8 Chassis Size and Weight................8 Table 9 Front Panel....................13 Table 10 Rear Panel....................14 Table 11 PCI Bus Throughput................
1. Introduction Overview PXIe-2519 is a high performance cost-effective 9-slot all hybrid PXI/PXIe chassis. It complements JYTEK PXIe-62509 9-slot sturdy all hybrid chassis with the new mechanical design that appeals to customers who wish to lower system cost but retain the high performance.
Link 4 is routed to PCIe switch and downstream to slot5~slot9 and PCI bus. The chassis can accommodate a maximum 4-slot width PXIe controller. 2.1.3 Peripheral Slot PXIe-2519 provides eight hybrid peripheral slots. It can accept the following peripheral modules: PXI Express Peripheral Module ...
2.1.5 PXI Local Bus The local bus on PXIe-2519 is a daisy-chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right, which by routing PXI Local Bus 6 signal between adjacent peripheral slots.
Mechanical Dimensions All dimensions are shown in mm (millimeters) Figure 3 Front View (PXIe-2519 Gen 3/Gen 2) Figure 4 Left Side View (PXIe-2519 Gen 3/Gen 2) PXIe-2519 | jytek.com | 9...
Page 14
Figure 5 Right Side View (PXIe-2519 Gen 3/Gen 2) Figure 6 Rear View (PXIe-2519 Gen 3/Gen 2) PXIe-2519 | jytek.com | 10...
Page 15
Figure 7 Top View (PXIe-2519 Gen 3/Gen 2) PXIe-2519 | jytek.com | 11...
2.4.4 Fan Mode PXIe-2519 provides the smart fan control mechanism as blow curve. It provides two fan modes. Table 4 Fan Mode When the Fan Switch is set to AUTO mode, the fan speed is controlled based on the measured temperature of sensor.
For PXI/PXIe modules cooling, there are two fans on the underside of the chassis draw cool air from the bottom side of chassis to be exhausted to the top sides of the chassis. Figure 9 PXI/PXIe Modules Cooling PXIe-2519 | jytek.com | 16...
2.5.2 Power Supply Cooling For power supply cooling, power supply’s fan draws cool air from the right side, to be exhausted through the left side and rear side of the chassis. Figure 10 Power Supply Cooling PXIe-2519 | jytek.com | 17...
PXIe-2519G3/G2 provides excellent throughput of PCI Bus as shown in below. There are two PCI Bus segments in the backplane. Slot2 to Slot5 is segment 1, and Slot6 to Slot9 is segment 2. Figure 11 PCI Bus Throughput for segment 1 PXIe-2519 | jytek.com | 18...
Page 23
Figure 13 PCI Bus Throughput for segment 2 Table 11 PCI Bus Throughput Note: PCI Bus theoretical maximum bandwidth is 132 MB/s. PXI-69846H is 4-ch 40 MS/s 16-bit digitizer, its bandwidth is 320 MB/s. PXIe-2519 | jytek.com | 19...
PCIe Bus Throughput PXIe-2519G3 provides excellent throughput of PCIe Bus as shown in below. Table 12 PCIe Bus Throughput PXIe-2519 | jytek.com | 20...
Page 26
Slot 1 is the system bandwidth test; its theoretical maximum bandwidth is 16 GB/s (PCIe Gen3 x16). Slot 2 to 5 are the slot bandwidth test; its theoretical maximum bandwidth is 4 GB/s (PCIe Gen3 x4). PXIe-2519 | jytek.com | 22...
4. Software Introduction to JYDM JYDM (JYTEK Device Management) is the latest equipment management software of JYTEK. Its main functions are as follows: Support GUI information display and management of PXI-2/6 standard equipment. Support trigger configuration of PXI-9 standard chassis.
Page 28
The left side of the JYDM interface is the hardware device column, and the right side is the device details column. You can view and configure the current device information, and upgrade the driver and firmware. Figure 15 JYDM GUI application program PXIe-2519 | jytek.com | 24...
Page 29
Note: JYTEK peripheral module driver has two parts: the shared common driver kernel software (FirmDrive) and the specific peripheral module driver. After firmware update of peripheral module, you need to cold restart your device. After driver update of peripheral module, you need to warm restart your ...
(T1 sensor is located on the top side of slot1.) Figure 15 Monitoring the Chassis Temperature Sensors Monitoring the chassis fan speed. (Fan1 module ia located on the bottom side of slot1.) Figure 16 Monitoring the Chassis Fan Speed PXIe-2519 | jytek.com | 26...
Chassis cooling control in JYDM PXIe-2519 chassis allow user to control the cooling capability via JYDM. Figure 17 Chassis Cooling Control in JYDM Target Temperature specifies the chassis temperature at which the maximum fan speed (100% duty cycle) is achieved as shown in below figure.
Page 32
Figure 17 Change Target Temperature to 45 °C PXIe-2519 | jytek.com | 28...
Open JYDM, set Valid PXI Resource Manager and Default PXI Trigger Manger to National Instruments, and then click Save to save the settings. Figure 19 Change PXI Trigger Manager Setting Open NI MAX after software installation and the devices can be identified: PXIe-2519 | jytek.com | 29...
Page 34
Figure 18 NI MAX GUI display JYTEK chassis and modules PXIe-2519 | jytek.com | 30...
This chapter provides the operation guides for PXIe-2519. Using PXIe-2519 with JYTEK PXI/PXIe Peripheral Modules Using PXIe-2519 with JYTEK PXI/PXIe peripheral modules is straightforward. JYTEK also provide a device management software to view the modules in the chassis. For more information, please visit our web www.jytek.com...
Page 36
But you can use “DAQmx Export Signal” to set appointed clock/trigger routing: Figure 21 DAQmx Export Signal DAQ synchronization reference code: Figure 22 DAQ Synchronization Reference Code PXIe-2519 | jytek.com | 32...
6. Optional Equipment Rack Mount Kits JYTEK provides optional hardware for installation of PXIe-2519 chassis into a server or rack. The rack mounting kits dimension as following figure. All dimensions are shown in mm (millimeters). Figure 25 PXIe-2519 rack mount kits dimension...
7. About JYTEK JYTEK China Founded in June, 2016, JYTEK China is a leading Chinese test & measurement company, providing complete software and hardware products for the test and measurement industry. The company is a joint venture between Adlink Technologies and a group of experienced professionals form the industry.
FirmDrive, upon which many our future hardware will be based. In addition to our own developed hardware, JYTEK also rebrands Adlink’s PXI product lines. In addition, JYTEK has other rebranding agreements to increase our hardware coverage. It is our goal to provide the complete product coverage in PXI and PCI modular instrumentation and data acquisition.
8. Statement The hardware and software products described in this manual are provided by JYTEK China, or JYTEK in short. This manual provides the product review, quick start, some explaination for JYTEK PXIe-2519 chassis. The manual is copyrighted by JYTEK.
Need help?
Do you have a question about the PXIe-2519 and is the answer not in the manual?
Questions and answers