JYTEK PXI-62700 User Manual

3u 18-slot pxi chassis and accessories

Advertisement

Quick Links

PXI-62700
3U 18-Slot PXI Chassis and Accessories
User's Manual
Manual Revision:1.00
Revision Date:
Jul.15,2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXI-62700 and is the answer not in the manual?

Questions and answers

Summary of Contents for JYTEK PXI-62700

  • Page 1 PXI-62700 3U 18-Slot PXI Chassis and Accessories User’s Manual Manual Revision:1.00 Revision Date: Jul.15,2016...
  • Page 2: Getting Service

    Getting Service Contact us should you require any service or assistance. SHANGHAI JYTEK Co., Ltd. Web site: http://www.jytek.com Address: (201203) 300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area, Shanghai, 201203 China Tel: +86-21-5047-5899 Fax: +86-21-5047-5899 Email: service@jytek.com...
  • Page 3: Table Of Contents

    3�5 Local Bus ������������������������������������������������������������������������������������������� 6 3�6 Trigger Bus ����������������������������������������������������������������������������������������� 6 3�7 System Reference Clock ��������������������������������������������������������������������� 9 4 Troubleshooting and Preventative Maintenance ���������������������������������������10 4.1 Troubleshooting the PXI-62700 ��������������������������������������������������������10 4�2 Cleaning �������������������������������������������������������������������������������������������10 4�2�1 Interior Cleaning ��������������������������������������������������������������������10 4�2�2 Exterior Cleaning �������������������������������������������������������������������10 4.3 Temperature Detection ���������������������������������������������������������������������11 4.4 Fan Hot-Swap Replacement ��������������������������������������������������������������11...
  • Page 4 Warranty Policy ����������������������������������������������������������������������������������������������26...
  • Page 5: List Of Tables

    List of Tables Table 4-1 Troubleshooting �������������������������������������������������������������������������������10...
  • Page 6 List of Figures Figure 1-1 Front View of the PXI-62700 chassis ������������������������������������������������ 2 Figure 1-2 Rear View of the PXI-62700 chassis �������������������������������������������������� 3 Figure 3-1 PXI Local Bus and Star Trigger Routing ���������������������������������������������� 8 Figure A-1 PXI-62700 Dimensions ��������������������������������������������������������������������14 Figure B-1 cBX-3018L front view Drawing ���������������������������������������������������������16...
  • Page 7: Introduction

    PXI trigger bus is divided into three segments. The star trigger signals are available from 3rd to 15th slots. The PXI-62700 is equipped with 460W + 460W redundant power units to provide reliable and easy to maintain power to the system. The status of system power supply, temperature, and cooling fans are monitored by the alarm module assembled in the chassis.
  • Page 8: Figure 1-1 Front View Of The Pxi-62700 Chassis

    Figure 1-1, 1-2 show some of the feature, and components of the PXI-62700 chassis. Figure 1-1 shows the front view of the PXI-62700. Figure 12 shows the rear view of the PXI-62700. Figure 1-1 Front View of the PXI-62700 chassis...
  • Page 9: Oem Options

    Please contact us for more details. 1�3�2 Chassis Color and Logo The standard color of PXI-62700 is beige. JYTEK provides custom chassis color or paint specific logo for OEM, with minimum order requirement. Please contact us for more details.
  • Page 10: Installation

    2 Installation 2�1 Power Budget Consideration Prior to installing any cards into the PXI-62700 chassis, please calculate the system power requirement. The power budget for every DC power sources shall also be checked, including +5V, +3.3V, +12V, -12V supply rail. Please refer to Appendix A for the maximum usable power.
  • Page 11: Grounding On The Mounting Holes

    The backplane is mounted on the PXI-62700 through all mounting holes by default, therefore the chassis ground is short to the logic ground. For applications that require isolation between the logic ground and the chassis ground, users can remove the screws on the GND mounting holes.
  • Page 12: Backplane Overview

    In accordance with the PXI specification, the local bus connections between all slots except slots 1 and 2. 3�6 Trigger Bus JYTEK PXI-62700 has three PXI separate trigger bus segments. The PXI trigger bus is divided into three separate trigger bus at these locations. The trigger bus divisions represented by...
  • Page 13 vertical bars on the front of the chassis. You can use triggers to synchronize the operation of several different PXI peripheral modules, or use one module to control carefully timed sequences of operations performed on other modules in the system. Modules can pass triggers to one another through trigger bus, allowing precisely timed responses to asynchronous external events the system is monitoring or controlling.
  • Page 14: Figure 3-1 Pxi Local Bus And Star Trigger Routing

    Figure 3-1 PXI Local Bus and Star Trigger Routing...
  • Page 15: 3�7 System Reference Clock

    3�7 System Reference Clock The PXI-62700 supplies the PXI 10MHz system clock signal (PXI_CLK10) independently to every peripheral slot. An independent buffer (having a source impedance matched to the backplane and a skew of less than 1ns between slots) drives the clock signal to each peripheral slot.
  • Page 16: Troubleshooting And Preventative Maintenance

    4 Troubleshooting and Preventative Maintenance 4�1 Troubleshooting the PXI-62700 Please refer to Table 4.1 to troubleshoot the PXI-62700 chassis. The table lists possible causes for power failure and recommends ways to correct the problem. Possible Cause What to Do PXI-62700 is not connected to power Make sure that the PXI-62700 is connected to a source.
  • Page 17: Temperature Detection

    4.5 Power Supply Unit Hot-Swap Replacement For the PXI-62700 chassis, there are four Green LED indicators for 3.3V, 5V, +12V, and -12V. There is also a Green LED for each power supply unit on the rear panel. The power unit is defective if the LED on the rear panel is extinguished or if the buzzer beeps continuously.
  • Page 18: A Specifications

    A Specifications Complies with PXI specifications and accepts modules compliant with CompactPCI, PICMG 2.0 specifications. Electrical AC Power Supply • 460W + 460W hot swappable 1+1 redundant power supply • Input voltage: 90-264VAC universal, full range • Input frequency: 47 to 63Hz •...
  • Page 19 System Monitoring • Power LED ◦ Voltage: +3.3V, +5V, +12V, -12V ◦ Color: Green ◦ ON while supplied • Temperature LED ◦ Temperature setting: 50°C (default), 60°C, 70°C ◦ Color: Amber ◦ ON for normal condition ◦ Flashes if exceeds setting temperature •...
  • Page 20: Figure A-1 Pxi-62700 Dimensions

    Figure A-1 PXI-62700 Dimensions Operating Environment • Ambient temperature range: 0 to 40°C • Relative humidity: 10 to 90%, non-condensing Storage Environment Temperature • Ambient temperature range: -20 to 70°C • Relative humidity: 5 to 95%, non-condensing Backplane • Backplane bare-board material: UL 94V-0 rated •...
  • Page 21 • Number of PXI-to-PXI bridges: 2 Shock and Vibration • Shock : 15G peak-to-peak, 11ms duration, non-operation • Random Vibration ◦ Operating: 5 to 500Hz, 0.5GRMS, each axis ◦ Non-operating: 5 to 500Hz, 1.88GRMS, each axis Safety and EMC/EMI Compliance •...
  • Page 22: B Backplane Drawing And Pin Assignments

    B Backplane Drawing and Pin Assignments B�1 Backplane Mechanical Drawing The following figures show the two parts of the backplanes and Mechanical Drawing. 11 12 13 14 15 16 17 18 3 4 5 1 2 3 4 5 6 Figure B-1 cBX-3018L front view Drawing 17 16 15 14 13 12...
  • Page 23: B�2 Pxi / Pci Bus Architecture

    B�2 PXI / PCI Bus Architecture PXI System Slot 1 Primary PCI Bus / Slot 2 Trigger Bus Controller Primary PCI Bus / Slot 3 64-bit PCI PXI Trigger bus Primary PCI Bus / Slot 4 (Group 1) Primary PCI Bus / Slot 5 Primary PCI Bus / Slot 6 CBX-R3018L Daisy chained...
  • Page 24: B�3 Backplane Cbx-3018L Connectors Pin Assignments

    B�3 Backplane cBX-3018L Connectors Pin Assignments B�3�1 PXI Connectors Pin Assignments System Slot (Slot #1) P1 Pin Assignment REQ64# ENUM# +3.3V AD[1] V(I/O) AD[0] ACK64# +3.3V AD[4] AD[3] AD[2] AD[7] +3.3V AD[6] AD[5] +3.3V AD[9] AD[8] C/BE[0]# AD[12] V(I/O) AD[11] AD[10] +3.3V AD[15]...
  • Page 25 GND AD[56] AD[55] AD[54] AD[53] GND AD[59] V(I/O) AD[58] AD[57] GND AD[63] AD[62] AD[61] AD[60] GND C/BE[5]# V(I/O) C/BE[4]# PAR64 GND V(I/O) PXI_BRSVB4 C/BE[7]# C/BE[6]# GND CLK4 GNT3# REQ4# GNT4# GND CLK2 CLK3 GND (SYS#) GNT2# REQ3# GND CLK1 REQ1# GNT1# REQ2# Star Trigger Slot (Slot #2) P1 Pin Assignment...
  • Page 26 15 GND PXI_BRSVA15 GND PXI_STAR6 PXI_LBR6 14 GND AD[35] AD[34] AD[33] AD[32] 13 GND AD[38] V(I/O) AD[37] AD[36] 12 GND AD[42] AD[41] AD[40] AD[39] 11 GND AD[45] V(I/O) AD[44] AD[43] 10 GND AD[49] AD[48] AD[47] AD[46] GND AD[52] V(I/O) AD[51] AD[50] GND AD[56] AD[55]...
  • Page 27 General Peripheral Slot (Slot #3~#6) P2 Pin Assignment GND PXI_BRSVA22 PXI_BRSVB22 PXI_BRSVC22 PXI_BRSVD22 PXI_BRSVE22 GND GND PXI_LBR0 PXI_LBR1 PXI_LBR2 PXI_LBR3 GND PXI_LBR4 PXI_LBR5 PXI_LBL0 PXI_LBL1 GND PXI_LBL2 PXI_LBL3 PXI_LBL4 PXI_LBL5 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 PXI_TRIG6 GND PXI_TRIG2 PXI_STAR (2) PXI_CLK10 GND PXI_TRIG1 PXI_TRIG0 PXI_TRIG7...
  • Page 28: B�3�2 Miscellaneous Connectors Pin Assignments

    REQ# / PXI P1 PXI P1 PXI P1 PXI P1 Slot # IDSEL PCI CLK GNT# Pin A3 Pin B3 Pin C3 Pin E3 BUS#3 Slot 13 S2_AD31 S2_0 S2_0 INTB# INTC# INTD# INTA# Slot 14 S2_AD30 S2_1 S2_1 INTA# INTB# INTC# INTD#...
  • Page 29 PCI VIO Selection Screw Terminals Position Signal Name V(I/O) +3.3V Note that the V(I/O) must be shorted to either +3.3V or +5V. The default factory setting is to short V(I/O) to +5V. J6 INH#: DC power inhibit signal Pin # Signal Name INH# J8 RST#: System reset signal...
  • Page 30 JP1: 10MHz Reference Clock Pin # Name 1-2 (default) Internal 10MHz system clock PXI_CLK10 External clock through the PXI_CLK10_IN on star trigger slot...
  • Page 31: Safety Instructions

    SAFETY INSTRUCTIONS Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. 1. Please read these safety instructions carefully. 2. Please keep this User‘s Manual for later reference. 3.
  • Page 32 Warranty Policy Thank you for choosing JYTEK. To understand your rights and enjoy all the aftersales services we offer, please read the following carefully: 1. Before using JYTEK’s products please read the user manual and follow the instructions exactly. 2. When sending in damaged products for repair, please attach an RMA application form.