PROBLEM
Motor will not run.
N003568
CAUSE
Fuse blown, circuit
breaker tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
Motor overload
protection switch
has tripped
18 - ENG
CORRECTION
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper
fuse. You should use
a time delay fuse.
Check for low
voltage problem.
Check the
extension cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the
extension cord.
Check wiring connection
inside terminal box.
Have checked by
a Trained Service
Technician.
Refer to Motor
Overload Protection
under Operation.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician