Chapter 4 - Periodic & Preventive Maintenance - Unitronics CP1 Manual

Table of Contents

Advertisement

The left and right arrow keys will toggle between "AUTO RESET" AND "MUST ACK". "AUTO RESET" will allow
the compactor to run for 30 minutes and then force a 10 minute cool down. Following the cool down, if the
photo eye remains blocked, the compactor will be allowed to run for another 30 minutes. This protects the
compactor from overheating resulting from a broken or misaligned photo eye. The" CHECK PHOTO EYE" alarm
will automatically clear when the photo eye no longer detects trash but will not clear during the 10 minute
cool down.
"MUST ACK" will shut down the compactor after a continuous 30 minute run cycle. The alarm must be
acknowledged – "1" TO RESET. In a tall building, this could eliminate noise at night.
CHAPTER 4 – PERIODIC & PREVENTIVE MAINTENANCE
Regular periodic attention coupled with a program of preventive maintenance will assure long-term, trouble-
free operation.
WARNING – NEVER SERVICE THE COMPACTOR UNLESS THE EMERGENCY STOP PUSHBUTTON IS DEPRESSED
AND THE WALL DISCONNECT HAS BEEN MOVED TO THE OFF POSITION.
Daily, do the following:
1.
Clean the photocell reflector with a soft damp cloth
2.
Clean the photocell lens itself with a soft damp cloth
3.
Check the alignment of the photo eye.
4.
Clean the compactor and power pack
5.
Clean the compactor room itself
6.
Check for hydraulic oil leaks
7.
Check for broken or missing parts, worn or frayed cables and hoses.