Atwood Mobile Products
1120 North Main Street • Elkhart, IN 46514
USA & Canada : 1-866-869-3118
Internet: http://www.atwoodmobile.com
English, Français (et Canada)
This instruction manual is for use by an authorized service technician
to install an Atwood – hydro flame™ furnace. Should you require
further information, contact your dealer or Atwood Mobile Products
LLC.
This furnace design has been certified for installation in recreation
vehicles as a MSP Category III furnace. Follow this installation
instruction to insure safe operation of the furnace. Failure to install
furnace according to this installation instruction nullifies the furnace
warranty.
TO THE INSTALLER: LEAVE THIS MANUAL WITH THE
APPLIANCE.
TO THE CONSUMER: RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety
hazards obey all safety messages following these symbols
WARNING
Avoid possible injury or
death
WARNING
FIRE OR EXPLOSION
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
Extinguish any open flame.
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container or
source.
Do not touch any electrical switch, or use any
phone or radio in the vehicle.
Do not start the vehicle's engine or electric
generator.
Contact the nearest gas supplier or qualified
service technician for repairs.
If you cannot reach a gas supplier or qualified
service technician, contact the nearest fire
department.
Do not turn on the gas supply until the gas
leak(s) has been repaired.
A qualified Service Technician
Service Center or gas supplier must perform
installation and service.
CAUTION
Avoid possible injury
and/or property damage
Installation of this appliance must be made in accordance with the
written instructions provided in this manual. No agent, representative
or employee of Atwood or other person has the authority to change,
modify or waive and provision of the instructions contained in this
manual.
Avoid possible injury or death
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to the
installation instructions and/or owner's manual provided with this
appliance. A qualified installer, service agency or the gas supplier must
perform installation and service.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Be sure the furnace and all ignition systems are "off" during any type of
refueling and while vehicle is in motion or being towed.
CRITICAL INSTALLATION WARNINGS
 DO NOT install furnace on material that restricts return air, like
carpet or any soft material such as vinyl.
 DO NOT install furnace where clearance to combustibles cannot be
maintained.
 DO NOT modify furnace or intake and exhaust vent in any way.
 DO NOT alter furnace for a positive grounding system.
 DO NOT hi pot furnace unless electronic ignition system (circuit
board) has been disconnected.
 DO NOT use battery charger to supply power to DC model furnace
even when testing.
 DO NOT use 120-volt AC current with DC models.
 DO NOT use furnace cabinet area as a storage compartment.
 DO NOT vent furnace with venting system serving another
appliance.
 DO NOT vent furnace to an outside enclosed porch area.
 DO NOT use for temporary heating of buildings or structures under
construction.
 Protect building materials from degrading from flue gas exhaust.
 Protect furnace electrical components from water.
 Compartment must be closed when operating unit.
 Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
 DO NOT use this furnace if any part has been under water.
 DO NOT use petroleum or citrus type cleaner on plastic parts, as
damage may occur.
Literature number 32472
hydro flame™
AFL Series Furnaces Models
AFLD35, AFLD40
AFLA35, AFLA40
Technical Installation Manual
Effective 8/15
WARNING
WARNING
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Atwood AFL Series

  • Page 1 No agent, representative LLC. or employee of Atwood or other person has the authority to change, This furnace design has been certified for installation in recreation modify or waive and provision of the instructions contained in this vehicles as a MSP Category III furnace.
  • Page 2: Table Of Contents

    Recommended 80 in 80 in 80 in 80 in Return Air MODEL NOMENCLATURE Minimum Hard 65 in 65 in 65 in 65 in Duct Return Air Atwood Cabinet Voltage Input Style Valve Model Minimum Furnace Size Btu/hr Type 48 in...
  • Page 3: General Furnace Installations

    when such standard is not applicable, the Standard for Manufactured Home Installations. (Manufactured Home Sites, Communities and Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240 MH Series M92 Canadian Standard for Mobile Homes.”  ANSI A 255.1 and/or CAN/CSA-Z240.6.2 MH Series, Mobile Homes ...
  • Page 4: Required Discharge

     Horizontal Bottom Discharge: This installation is for horizontally FLEXIBLE DUCTING installed units and can be used with the addition of one duct any When designing flexible duct systems: location except the top two.  Follow ducting configuration shown  Vertical Bottom Discharge: Installation of the furnace in a ...
  • Page 5: Small Vent Installation

     Doors are designed to allow water drainage in either horizontal or vertical installations. Proper location of vent assembly is important for proper exhausting of fumes and proper function of furnace.  NOTE: RTV type sealant must be applied to the bezel and casing at the bottom right side to prevent possible water wicking into the coach.
  • Page 6: Horizontal Floor Discharge Cutout

      DO NOT install floor registers within 2 feet of return air openings. Before furnace is, connected piping systems are to be tested to be leak free. The test must maintain air pressure of a least 6” of See ducting option from casing top and bottom areas. Hard ducting must be sealed to the furnace and floor to insure proper mercury or 3 PSI for at least 10 minutes.
  • Page 7: Valve Conversion

    CAUTION PROPERTY DAMAGE On units with 12 volt connection are for low-voltage battery or direct current only. Do not connect to 120 or 240 volts AC. CAUTION PROPERTY DAMAGE This furnace is designed for negative ground 12 volts DC only. DO NOT attempt to alter furnace for a positive ground system or connect the furnace directly to 120 OR 240 volts AC.
  • Page 8: 120 Volt Ac Wiring

    EXTERIOR wall location must have a 3/4” spacer between Locate equipment at least five feet (5’) from furnace location. If this thermostat and exterior wall. distance cannot be maintained, Atwood has a kit which can be Follow manufacture’s installation instructions provided with purchased. See parts list.
  • Page 9: To Shut Down

    TO SHUT DOWN Set the thermostat to lowest setting, then move lever to “OFF” Standard 3 tries for Ignition Controls position. Turn manual shut off valve (if so equipped) to the “OFF” position. DIAGNOSTIC CHART Do not force. FAULT LED INDICATION LOCKOUT IGNITION CONTROL DIAGNOSTIC CODES Internal Circuit Board...
  • Page 10 AFLA35, AFLA40 WIRING AND LADDER DIAGRAMS...
  • Page 14 Figure 2 Valve Kit 31098 Figure 1 Small Paddle Kit 31094 Figure 3 Electrode Adjustment...