Suitable batteries

General

Fronius explicitly points out that the third-party batteries are not Fronius
products. Fronius is not the manufacturer, distributor or retailer of these batter-
ies. Fronius accepts no liability and offers no service or guarantees for these bat-
teries.
Obsolete firmware/software states may lead to incompatibilities between the in-
verter and the battery. In this case, the following steps are to be performed:
1
2
Read this document and the Installation Instructions before installing and com-
missioning the external battery. The documentation is either enclosed with the
external battery or can be obtained from the battery manufacturer or their ser-
vice partners
All documents associated with the inverter can be found at the following ad-
dress:
https://www.fronius.com/en/solar-energy/installers-partners/service-support/
tech-support
Limitations in
If the DC voltage exceeds 520 V, the battery can no longer be charged or dis-
operation
charged. The voltage of 520 V is rarely exceeded during normal operation of the
inverter.
When the output power of the inverter is reduced, the operating point shifts to-
wards higher DC voltages. The following conditions during normal operation can
lead to the DC voltage of 520 V being exceeded:
-
-
-
-
BYD Battery-
BYD Battery-Box Premium HVS
Box Premium
Fronius Primo GEN24 3.0 - 6.0*
Fronius Primo GEN24 3.0 - 6.0 Plus
Number of battery modules
Battery parallel operation**
BYD Battery-Box Premium HVM
Fronius Primo GEN24 3.0 - 6.0*
26
Update battery software – see the battery documentation.
Update inverter firmware – see
Overdimensioning of the PV generator.
Feed-in limitation (e.g. zero feed-in).
Specifications of the grid operator (e.g. mains voltage-dependent power re-
duction).
Backup power mode. If the 520 V voltage is exceeded during backup power,
backup power operation may be restricted. Therefore, an open circuit voltage
of max. 520 V is recommended.
Update
on page 112.
5.1
2
8.3
11.0
13.8
7.7
10.2
12.8
3
4
5
16.6
19.3
22.1