Table of Contents

Advertisement

Quick Links

Operating manual
Clou Xtra 945026
www.austroflamm.com

Advertisement

Table of Contents
loading

Summary of Contents for Austroflamm Clou Xtra 945026

  • Page 1 Operating manual Clou Xtra 945026 www.austroflamm.com...
  • Page 2 Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com Edited by: Olivera Stojanovic Illustrations: Konstruktion Text: Technical department (Austroflamm) Copyright All Rights reserved. The contents of these instructions may be reproduced or distributed only with the consent of the publisher! Printing, spelling and typographical errors reserved.
  • Page 3: Table Of Contents

    Operating manual Clou Xtra 945026 Contents Contents General information ............................Copyright.............................. Purpose of the manual ............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control............................. Abbreviations ............................Safety ..................................Importance of the safety instructions ....................Warning of sources of danger ......................
  • Page 4 Contents Operating manual Clou Xtra 945026 9.2.3 Rearranging the flue pipe connection ....................30 9.2.4 Converting external air connection....................32 9.2.5 Removing the HMS..........................33 10 Settings................................. 34 10.1 Aligning the stove..........................34 10.2 Adjusting the door ..........................34 10.3 Adjusting the door lock ........................
  • Page 5: General Information

    Operating manual Clou Xtra 945026 1 | General information General information You have decided in favor of an Austroflamm stove. Congratulations on your decision and thank you for your trust. Correct operation and care are essential for trouble-free operation and long service life.
  • Page 6: Purpose Of The Manual

    2 | Purpose of the manual Operating manual Clou Xtra 945026 Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
  • Page 7: Abbreviations

    Operating manual Clou Xtra 945026 2 | Purpose of the manual Abbreviations Abbreviation Meaning Heat Memory System Stoves...
  • Page 8: Safety

    3 | Safety Operating manual Clou Xtra 945026 Safety In this manual we give you numerous safety instructions for the safe operation of your stove. These in- structions are characterized differently as follows, depending on their importance: Importance of the safety instructions NOTICE Particular behaviour and/or activities that are required for safe working.
  • Page 9: Special Types Of Danger And Personal Protective Equipment

    Operating manual Clou Xtra 945026 3 | Safety • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
  • Page 10: Product Overview

    Operating manual Clou Xtra 945026 Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested with a type A1 self-closing and locking door under EN test EN 13240. NOTICE Operation is only permissible with closed/bolted door.
  • Page 11 Operating manual Clou Xtra 945026 4 | Product overview Fig. 2: Safety distances OPEN CLOSED Convection air controller OPEN CLOSED Primary/secondary air control Fig. 3: Air control...
  • Page 12: Energy Label

    4 | Product overview Operating manual Clou Xtra 945026 Energy label Fig. 4: Clou Xtra energy label Positioning of the nameplates Here we show where you can find the nameplate. You can find a copy of the nameplate of your stove on the back of this manual.
  • Page 13: Technical Data

    Operating manual Clou Xtra 945026 5 | Technical data Technical data As a type 1 stove, a connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
  • Page 14 5 | Technical data Operating manual Clou Xtra 945026 Bituminous coal Brown coal briquettes Peat briquettes Briquettes made of a mix- ture of fossil fuels Other fossil fuels Briquettes made of a mix- ture of biomass and fossil fuels Other mixture made of...
  • Page 15: General Specifications

    Operating manual Clou Xtra 945026 5 | Technical data Specification in mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, section i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, letter a, section i, point 2 and 3.)
  • Page 16: Transport, Handling And Storage

    6 | Transport, handling and storage Operating manual Clou Xtra 945026 Transport, handling and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the stove, check that all movable parts are working. Any defects before the installation of the stove must be reported.
  • Page 17: Requirements At The Installation Location

    When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (diameter 150 mm). The connection can, as described in these instructions, be rearranged to the bottom. When connecting with other pipe diameters the approval of your responsible chimney sweep is required.
  • Page 18: Floor Load-Bearing Capacity

    7 | Requirements at the installation location Operating manual Clou Xtra 945026 Floor load-bearing capacity Before installing, verify whether the load-bearing capacity of the substructure can withstand the weight of your Austroflamm stove. Floor condition In the radiation area of the pane (in front of the stove), the floor must not be combustible.
  • Page 19: Fuel Material/-Quantity

    Operating manual Clou Xtra 945026 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
  • Page 20 8 | Fuel material/-quantity Operating manual Clou Xtra 945026 Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
  • Page 21: Fuel Quantity

    Maximum amount of fuel to be deposited: 1.9 kg wood or briquettes. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
  • Page 22: Installation

    9 | Installation Operating manual Clou Xtra 945026 Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation.
  • Page 23: Execution

    Operating manual Clou Xtra 945026 9 | Installation Execution 9.2.1 Removing side cladding 1) Detach cover (if mounted). Fig. 8: Detaching the cover 2) Loosen the two locking screws (M5/TX25) of the steel side cladding, right and left inside top. Fig. 9: Loosening the screws...
  • Page 24: Converting The Door Handle (Softlock)

    9 | Installation Operating manual Clou Xtra 945026 3) Lift up and detach the side cladding. Fig. 10: Detaching the side cladding 9.2.2 Converting the door handle (softlock) 1) To remove the cover and only the right side cladding, proceed as described in the section Removing the side cladding [}on page 23].
  • Page 25 Operating manual Clou Xtra 945026 9 | Installation 3) Remove original latch bolt. Fig. 12: Removing the latch bolt 4) Undo screws of the existing door handle. Fig. 13: Loosening the screws 5) Remove door handle. Fig. 14: Removing the door handle...
  • Page 26 9 | Installation Operating manual Clou Xtra 945026 6) Detach wooden handle (1) from the original door handle and use the same screws to attach it to the new door handle. Fig. 15: Detaching the wooden handle...
  • Page 27 Operating manual Clou Xtra 945026 9 | Installation 7) Mount new catch in the original position. Fig. 16: Mounting the new catch Fig. 17: New catch mounted...
  • Page 28 9 | Installation Operating manual Clou Xtra 945026 8) Mount the new door handle in the original position. Fig. 18: Mounting the new door handle Fig. 19: New door handle mounted 9) Close door slowly. In the process, note whether the door latches correctly into the catch.
  • Page 29 Operating manual Clou Xtra 945026 9 | Installation 10) Should the door not correctly engage the catch, the four screws can be used to adjust the catch upwards, downwards, forwards and backwards. Fig. 21: Adjusting the door catch 11) Remount side cladding and attach cover.
  • Page 30: Rearranging The Flue Pipe Connection

    9 | Installation Operating manual Clou Xtra 945026 9.2.3 Rearranging the flue pipe connection 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 23].
  • Page 31 Operating manual Clou Xtra 945026 9 | Installation 5) Replace parts and reinstall. Fig. 25: Replacing cover and bracket Fig. 26: Cover and bracket replaced 6) Remount side cladding and attach cover. Fig. 27: Remounting the side cladding and attaching the cover...
  • Page 32: Converting External Air Connection

    9 | Installation Operating manual Clou Xtra 945026 9.2.4 Converting external air connection 1) To remove the cover and the side cladding, Proceed as described in the section Removing the side clad- ding [}on page 23]. 2) Using a saw, remove the perforated cut-out to the side cladding (rear).
  • Page 33: Removing The Hms

    Operating manual Clou Xtra 945026 9 | Installation 9.2.5 Removing the HMS 1) To remove the cover and the side cladding, Proceed as described in the section Removing the side clad- ding [}on page 23]. DANGER Tilt hazard Before the HMS bricks are removed, it must be ensured that the stove does not tip forward.
  • Page 34: Settings

    10 | Settings Operating manual Clou Xtra 945026 Settings 10.1 Aligning the stove 1) First the cover and the side cladding must be de- tached. ð Proceed as described in the section Removing the side cladding. 2) There are two screw on the back of the stove. These can be used to align the stove.
  • Page 35 Operating manual Clou Xtra 945026 10 | Settings 4) Undo screws and removing cladding. Fig. 34: removing upper front cladding 5) Undo the screws at the bottom and remove cladding. Fig. 35: removing lower front cladding...
  • Page 36: Adjusting The Door Lock

    10 | Settings Operating manual Clou Xtra 945026 6) The door can be adjusted on the screws. 7) Using the screws (1) the door can be adjusted up, down, left and right. 8) Using the grub screws (2) the door can be adjusted in and out.
  • Page 37: Adjusting The Closing Pressure Of The Door

    Operating manual Clou Xtra 945026 10 | Settings 2) Using the marked screws the door lock can be adjus- ted upwards, downwards, forwards and backwards. Fig. 38: Adjusting the door lock 10.4 Adjusting the closing pressure of the door Only the left side cladding needs to be removed for this step.
  • Page 38 10 | Settings Operating manual Clou Xtra 945026 3) Undo the screws at the bottom and remove cladding. Fig. 40: removing lower front cladding ü At the bottom of the door there is a bolt which can used to adjust the door closing pressure.
  • Page 39: Commissioning

    Operating manual Clou Xtra 945026 11 | Commissioning Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
  • Page 40: Operation

    12 | Operation Operating manual Clou Xtra 945026 Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
  • Page 41: Heating In The Transition Period

    Operating manual Clou Xtra 945026 12 | Operation 7) Close the door. ð It is best to allow the first layer of wood to combust without altering the air damper setting. ð If only the bed of embers is left (no more flames), you can place another layer of log.
  • Page 42: Maintenance

    13 | Maintenance Operating manual Clou Xtra 945026 Maintenance 13.1 Changing the seal on the door 1) Remove old seal from the door. 2) Glue in new seal with a suitable adhesive (e.g. silicon B310). Fig. 45: Changing the seal...
  • Page 43: Cleaning

    Operating manual Clou Xtra 945026 14 | Cleaning Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
  • Page 44: Cleaning The Door Window

    14.3 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
  • Page 45: Cleaning Surfaces

    Operating manual Clou Xtra 945026 14 | Cleaning 14.4 Cleaning surfaces • Varnished surfaces may only be cleaned with a soft cloth (if necessary damp). • Soak up dissolved dirt with absorbent cloths or household paper. • For stainless steel surfaces there are also special cleaners.
  • Page 46: Help

    15 | Help Operating manual Clou Xtra 945026 Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss extend chimney/measure...
  • Page 47: Firebox Lining

    Operating manual Clou Xtra 945026 15 | Help Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
  • Page 48: Accessories

    16 | Accessories Operating manual Clou Xtra 945026 Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional. Xtra heat storage technology Your stove is equipped with the unique Xtra heat storage technology.
  • Page 49: Spare Parts

    Operating manual Clou Xtra 945026 17 | Spare parts Spare parts HMS incl. cover Fig. 51: HMS incl. cover Item no. Quantity Item Article no. HMS complete 72403 Xtra cover, complete 778981...
  • Page 50 17 | Spare parts Operating manual Clou Xtra 945026 Fig. 52: HMS Item no. Quantity Item Article no. HMS back part, center right 724010 HMS back part, right 724011 HMS back part, left 724012 HMS back part, center left 724041...
  • Page 51 Operating manual Clou Xtra 945026 17 | Spare parts Keramott Fig. 53: Keramott Item no. Quantity Item Article no. Keramott floor left 724001 Keramott floor rear 724002 Keramott panel left 724003 Keramott panel side 724004 Keramott panel rear 724005 Keramott floor right...
  • Page 52 17 | Spare parts Operating manual Clou Xtra 945026 Softlock Fig. 54: Softlock Item no. Quantity Item Article no. Washer without chamfer for M5 DIN125 718062-15 Grub screw with hex and eyebolts M4x12 DIN916 718064-92 Grub screw with hex and eyebolts M4x6 DIN916 718459-92 Safety washer for shafts Ø4 DIN6799...
  • Page 53 Operating manual Clou Xtra 945026 17 | Spare parts Firebox door Fig. 55: Firebox door Item no. Quantity Item Article no. Gasket 8x2x20, self-adhesive 710096 O-seal Ø14x1705 714223 Hollow seal w/wire Ø06x1545 718183 Firebox door ash collection tray complete 724014 Firebox door window holder top...
  • Page 54: Dismantling

    18 | Dismantling Operating manual Clou Xtra 945026 Dismantling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer.
  • Page 55: Disposal

    NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
  • Page 56 19 | Disposal Operating manual Clou Xtra 945026 Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
  • Page 57: Guarantee / Warranty

    For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
  • Page 58: Data Processing

    If you consent to the appropriate handling of your personal data for the following purposes, please tick this box. o I hereby agree that Austroflamm GmbH and AUSTROFLAMM Service GmbH & Co KG may send me service reminders and offers on other products from Austroflamm GmbH for the purposes of advert- ising via E-Mail/ SMS/ telephone.
  • Page 59: Start Up Log

    Operating manual Clou Xtra 945026 22 | Start up log Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number...
  • Page 60: Service Report

    23 | Service Report Operating manual Clou Xtra 945026 Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 61 Operating manual Clou Xtra 945026 23 | Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 62 Notizen / notes / appunti / remarques...
  • Page 63 Notizen / notes / appunti / remarques...
  • Page 64 Vollständigkeit / completeness / completo / complet Geprüft von / checked by / controlled da / contrôlé par ____________________________________________________ Datum / date / data / date ____________________________________________________ AUSTROFLAMM GMBH Austroflamm-Platz 1 A- 4631 Krenglbach Tel: +43 (0) 7249 / 46 443 www.austroflamm.com...

Table of Contents