Fascia

Fig. 2
1
G On/Off button for refrigerator
compartment
Switches the refrigerator
compartment on and off separately.
2
G On/Off button for the freezer
compartment
Switches the freezer compartment
on and off separately.
Observe ambient
temperature and

ventilation

The climatic class can be found on the
rating plate (Fig. e) and it indicates the
ambient temperatures at which the
appliance can be operated.
Climatic class
SN
N
ST
T
Ventilation
Fig. 3
The air which is heated on the rear panel
and the side panels must be able to es
cape unobstructed. Otherwise, the refrig
erating unit must work harder and the
power consumption is increased. There
fore, never cover the ventilation openings.
The appliance must be free standing.
The appliance must be 3 cm from the wall
and adjacent kitchen units.
Permitted ambient
temperature
+10 C to 32 C
+16 C to 32 C
+18 C to 38 C
+18 C to 43 C
Connecting
the appliance
After installing the appliance, wait at least
½ hour before switching on the appliance.
During transportation the oil in the
compressor may have flowed into the
refrigeration system.
To enable your refrigerator to be used with
serve@Home, you will require a special
accessory, the system interface, which
is available from specialist outlets. The
system interface must be inserted into the
slot at the rear of your refrigerator. Follow
the installation instructions enclosed with
the system interface.
Before switching on the appliance for the
first time, clean the interior (see Cleaning).
The socket should be freely accessible.
Connect the appliance to 220 240 V/
50 Hz alternating current via a correctly
installed earthed socket. The socket must
be fused with a 10 A fuse or higher.
If the appliance is to be operated in
a non European country, check on the
rating plate whether the indicated
voltage and current type correspond
to the values of your mains supply.
The rating plate is situated in the
bottom left hand side of the appliance.
The mains connection cable may be
replaced by an electrician only.
Warning!
!
Never connect the appliance to
electronic energy saver plugs
(e.g. Ecoboy: Sava Plug) or to power
inverters which convert the direct
current to 230 V alternating current
(e.g. solar equipment, power supplies
on ships).