Door Lock/s
The freezer may be fitted with bracket locks or key locks, located above or below each door. Bracket locks require a lock
(padlock or similar) through the brackets to lock the door. Key locks can be locked with the supplied key.
Electronic Controller
The electronic controller regulates the freezer's temperature, signals alarms and captures operational
information. The freezer temperature is factory set for storage of perishable product (all shelves maintain
L1 temperature range: less than -18°C (can spike up to -15°C).
To customise the freezer settings to your requirements and view historical data, download the
SKOPE-connect app from the Google Play Store or Apple App Store, and connect via Bluetooth
Lights
The freezer lights switch on and off automatically depending on freezer use.
Cleaning
Ensure the freezer is unplugged from the power supply before cleaning.
Wipe the inside and outside of the cabinet with a damp cloth, taking care to keep moisture away from electrical parts.
The condenser coil must be kept clean. SKOPE strongly urges cleaning the condenser coil every three months.
Do NOT use hard or sharp tools to clean the coil as these may cause damage.
Clean the Coil
1. Unplug the freezer from the power supply, and unplug any lit sign panels.
2. Remove the front panel from the top of the
cabinet.
WARNING: Front panel is heavy, a two person lift is
recommended.
3. Brush the condenser coil with a soft brush to
remove any dust and fluff.
4. Refit the sign assembly and reconnect to the
power supply.
Important
When refitting, ensure the tabs on the back of the
sign are located in the notches on top of the cabinet,
and that the sign is pushed fully in and secure.
PRN80226 Rev. 1.0 Apr. 2022
Freezer
Coil
Tab and notch