PRISM® SUSPEND 4000
INSTALLATION OF PRISM® SUSPEND 4000
TOOLS NEEDED
• 5/16" Nutdriver
• 3/8" Nutdriver
• 1/2" Nutdriver
• 9/16" Nutdriver
• 9/16" Box Wrench
• Appropriate Hoist and Rigging
• Liquid Sealant
• Strip Foam Gasket
• Miscellaneous Hand Tools
• Ladder/Lift
• Drill or Impact
• 1/4" Drill Bit
Step 1 – Unpack the Unit
Place pallet near intended installation location and unpack in
preparation for assembly.
Using supplied door key, unlock/open door. Remove control
panel, dust bin and other components from inside unit.
FIGURE A.1
Hopper
Filter Boxes
Step 2 – Connect Fan Motor Cable
FIGURE A.2
1. Determine power cable
length that will reach from
fan motor (at pre-determined
installation location) to power
disconnect.
4. Use supplied loop
clamps to secure
power cable to
unit and
protect
it from
sharp
edges.
Step 3 – Hoist the Unit for Hopper Assembly and
Installation
FIGURE A.3
LIFT METHOD 2
1. Open door as shown.
2. Using fork truck, lift
unit under tube sheet
between lter
clamping rails.
CAUTION: ENSURE
UNIT'S DOOR DOES
NOT GET PINCHED
BY FORK TRUCK'S
MAST & LOAD
BACKREST.
VERIFY
FORKS
ARE
INSERTED
TO WITHIN
2" OF
UNIT'S
REAR
PANEL
BEFORE
LIFTING
UNIT.
A-4
INSTALLATION
2. Route power into fan motor
through this cord grip.
3. Connect cable per fan
motor instructions.
LIFT METHOD 1
1. Use OSHA approved
lifting sling or chains
rated to 1250 lbs when
used with corner lifting
brackets (similar to
shown).
2.
Lift with fork truck or
crane.