Overview Of Electrical Connections For External And Internal Actuators - Daikin Altherma EWSAH06DA9W Installation Manual

Hide thumbs Also See for Altherma EWSAH06DA9W:
Table of Contents

Advertisement

(a)
#
Power supply
2 Split power supply
(2×(1N~, 50 Hz, 230 V AC))
1N~, 50 Hz,
230 V AC
C5
C1
1N~, 50 Hz,
230 V AC
(a)
For details of C1 and C5, see
supply" [ 4  14].
power
(b)
Normal operation: backup heater = maximum 3 kW
Emergency operation: backup heater = maximum 6 kW
5.2
Overview of electrical connections
for external and internal actuators
Item
Power supply
See
"5.3 To connect the main power
supply" [ 4  14].
Remote outdoor
See
"5.4 To connect the remote outdoor
sensor" [ 4  16].
sensor
Shut-off valve
See
"5.5 To connect the shut-off
valve" [ 4  17].
Electricity meter
See
"5.6 To connect the electricity
meters" [ 4  17].
Domestic hot water
See
"5.7 To connect the domestic hot water
pump" [ 4  18].
pump
Alarm output
See
"5.8 To connect the alarm
output" [ 4  18].
Space cooling/heating
See
"5.9 To connect the space cooling/
operation control
heating ON/OFF
Changeover to
See
"5.10 To connect the changeover to
external heat source
external heat
control
Power consumption
See
"5.11 To connect the power
digital inputs
consumption digital
Safety thermostat
See
"5.12 To connect the safety thermostat
(normally closed
Low pressure switch
See
"5.13 To connect the low pressure
on central water loop
switch on the central water loop
side" [ 4  21].
Thermostat for passive
See
"5.14 To connect the thermostat for
cooling
passive
LAN adapter
See
"5.15 LAN
connections
EWSAH/X06DA9W
Daikin Altherma 3 WS
4P675759-1 – 2021.10
(b)
Operation
Emergency
"5.3 To connect the main
Description
output" [ 4  19].
source" [ 4  20].
inputs" [ 4  20].
contact)" [ 4  21].
cooling" [ 4  22].
adapter" [ 4  22].
5 Electrical installation
Item
Room thermostat
See:
(wired or wireless)
▪ Installation manual of the room
▪ Addendum
Wires for wired room thermostat: (3
for cooling/heating operation; 2 for
heating only operation)×0.75 mm²
Wires for wireless room thermostat: (5
for cooling/heating operation; 4 for
heating only operation)×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Heat pump convector
See:
▪ Installation manual of the heat
▪ Addendum
Wires: 4×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Remote indoor sensor
See:
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Current sensors
See the installation manual of the
current sensors.
Wires: 3×2. Use part of the cable
(40 m) delivered as accessory.
[9.9.1]=3 (Power consumption
control = Current sensor)
[9.9.E] Current sensor offset
Description
thermostat (wired or wireless)
book
for
optional
equipment
pump convectors
book
for
optional
equipment
indoor sensor
book
for
optional
equipment
Installation manual
13

Advertisement

Table of Contents
loading

This manual is also suitable for: