5/20/2018
7.2
Contact Springs/Detent Spring in Control Handle

(Bike Handle)

- Remove the throttle trigger -
7.1.
Lift contact spring (1) a little and
remove the throttle cable (2).
Remove spring from seats (1)
and peg (2).
Remove contact spring from peg
(1) and collar screw (2).
34
http://slidepdf.com/reader/full/stihl-fs-350-service-manualpdf
STIHL FS 350 Service manual.pdf - slidepdf.com
see
Take out slide control's collar
screw (1).
Remove detent spring (2).
Pull slide control out of handle
molding.
Assemble in the reverse
sequence.
- Engage contact spring correctly
in groove of collar screw.
7.3
Throttle Trigger/Interlock 

Lever (Loop Handle)

FR 350/450
Use screwdriver (1) 5910 890
2301 to remove screw.
Push guard (2) forward.
All models
Warning: To avoid risk of electric
shock, do not start the unit while
the control handle is open.
Use screwdriver (1) 5910 890
2301 to take out the screws.
- Remove handle molding.
Remove torsion spring.
FS 120, 200, 300, 350, 400, 450, FR 350, 450
35/63