Download Print this page
Ashland Pump UT57 Operation, Performance, And Specifications

Ashland Pump UT57 Operation, Performance, And Specifications

High capacity transfer utility pump

Advertisement

Quick Links

OPERATION, PERFORMANCE,
AND SPECIFICATIONS
High Capacity
Transfer
Utility Pump
• Thank you for purchasing this pump. Take the time to
read the instructions carefully before using this
product. We strongly recommend that you keep this
instruction manual in a safe place for future reference.
• Please refer to our website and the Products Center for
additional installation and operation instructions.
• Refer to the website for replacement parts information.
LIMITED WARRANTY
This pump is warranted to be free from defects in material and workmanship
and to perform within applicable specifications for a period of one year from
date of installation or 18 months from date of manufacture, which ever comes
first. Obligation under this warranty is limited to repairing or replacing any part
thereof, which shall within one year be returned to us with transportation charges
prepaid, and proved to be defective.
The above limited warranty takes the place of all other warranties, express or
implied and correction of such defects by replacement or repair shall constitute
a fulfillment of all obligations under the terms of the warranty, which specifically
EXCLUDES any incidental damages caused by or associated with this product or
its use. The warranty does not cover any unit which has been damaged either in
transit or by misuse, accident or negligence. No warranty or representative not
contained herein shall be binding.
PERFORMANCE
Model
HP
UT57
1/2
GPM at Total Feet of Head
0'
20'
25
18
Model UT57
MARKS AND MEANING:
DANGER
which, if not avoided, WILL result in death or
serious injury.
WARNING
which, if not avoided, MAY result in death or
serious injury.
CAUTION
which, if not avoided, MAY result in minor or
moderate injury.
40'
60'
14
1
"Danger" indicates an
imminent hazardous situation
"Warning" indicates an
imminent hazardous situation
"Caution" indicates a
potentially hazardous situation
80'
10
4.8
101'
0

Advertisement

loading
Need help?

Need help?

Do you have a question about the UT57 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ashland Pump UT57

  • Page 1 • Please refer to our website and the Products Center for additional installation and operation instructions. • Refer to the website for replacement parts information. Model UT57 MARKS AND MEANING: LIMITED WARRANTY This pump is warranted to be free from defects in material and workmanship “Danger”...
  • Page 2 Each Ashland Pump is individually factory tested to ensure proper performance. Closely following these Make sure lifting handles are securely...
  • Page 3 Utility Pumps Model: UT57 Specifications .75” NPT 5.6” 6.9” .70” 9.6”...
  • Page 4 Utility Pumps Model: UT57 Performance GALLONS PER MINUTE...
  • Page 5: Overload Protection

    Utility Pumps Model: UT57 Installation Do not work on pump until power is unplugged. (f) Pumping chemicals or corrosive liquids, other than motor oil. Do not cut off ground pin or use an adapter fitting. (g) Pumping gasoline or other flammable liquids Do not use an extension cord.
  • Page 6 Utility Pumps Model: UT57 Troubleshooting Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes, under flooded conditions. Contact your local electric company or a qualified licensed electrician for disconnecting electrical...
  • Page 7 Nous recommandons fortement que vous gardiez ce manuel d’instructions dans un endroit sûr pour la référence future. • Référez-vous à notre site Web et au Centre des Produits Modèle UT57 pour les instructions supplémentaires d’installation et de fonctionnement s’il vous plaît .
  • Page 8 Pompes utilitaires Modèle: UT57 Spécifcations Ne pas utiliser ces pompes Avant l’installation, lisez ce qui suit dans les instruc- ADVERTISSEMENT dans l’eau plus de 145 ° F.Ne tions attentivement. Le défaut de suivre les instruc- dépassez pas les performances maximales recommandées tions et l’information de sécurité...
  • Page 9 Pompes utilitaires Modèle: UT57 Spécifcations .75” NPT 5.6” 6.9” .70” 9.6”...
  • Page 10 Pompes utilitaires Modèle: UT57 Performance GALLONS PAR MINUTE...
  • Page 11: Protection De Surcharge

    Pompes utilitaires Modèle: UT57 Installation CONNEXION DES FILS ELECTRIQUES Ne travaillez pas sur la pompe jusque l’alimentation est débranchée. Vérifiez que le voltage et ADVERTISSEMENT Ne coupez pas la broche de terre ou utiliser un adaptateur la fréquence de la pompe approprié.
  • Page 12 Pompes utilitaires Modèle: UT57 Dépannage ADVERTISSEMENT Avant de réparer une pompe, coupez toujours le disjoncteur d’alimentation principale, et puis débranchez la pompe. Assurez-vous que vous n’êtes pas debout dans l’eau et portez des chaussures à semelle de protection isolés, dans des conditions inondées. Contactez votre compagnie d’électricité locale ou un électricien agréé...
  • Page 13 • Por favor, visite nuestro sitio de web y centro de productos para instrucciones adicionales de instalación y operación e información de piezas de repuesto. Modelo UT57 • Consulte el sitio web de información sobre las piezas de repuesto. GARANTIA LIMITADA MARCAS Y SIGNIFICADO “Peligro”, una situación de peligro...
  • Page 14 Bombas de Utilidad Modelo: UT57 Información General de Seguridad Antes de la instalación, lea atentamente las siguientes instruc- No nos estas bombas en el agua más ADVERTENCIA ciones. El incumplimiento de información de instrucción y de de 145 ° F. No exceda fabricante seguridad podría causar lesiones corporales graves, la muerte y...
  • Page 15 Bombas de Utilidad Modelo: UT57 Especifcaciones .75” NPT 5.6” 6.9” .70” 9.6”...
  • Page 16 Bombas de Utilidad Modelo: UT57 Rendimiento Galones por minuto...
  • Page 17 Bombas de Utilidad Modelo: UT57 Instalación No trabaje en la bomba hasta que la alimentación (g) La gasolina de bombeo u otros líquidos está desenchufada. inflamables (h) Toda la tubería debe estar limpia y libre No corte pin de tierra o utilice un adaptador apro- de toda materia extraña para evitar la...
  • Page 18 Bombas de Utilidad Modelo: UT57 Solución De Problemas Siempre desconecte la bomba de la fuente de alimentación eléctrica antes de manipular. Si el ADVERTENCIA sistema no funciona correctamente, lea atentamente las instrucciones y realizar recomendacio- nes de mantenimiento. Si los problemas de funcionamiento no se corrigen, la siguiente tabla puede ser de ayuda en la identificación y corregirlos.