Quick Links

EZY-LAN Wireless alarm panel with Ethernet + Wi-Fi + GSM + LTE
1
Identification of the parts
FRONTAL VIEW
1 – led power
2 – led Ethernet
3 – led Wi-Fi
12
8
BOTTOM VIEW VERSION HW 3B
12
8
BOTTOM VIEW VERSION HW 4A/4B
8 – button PWR
9 – button RJ45
10 – nanoSIM housing
4 – led GSM + LTE
5 – programmable central button
6 – multicolor led ring
10
9
11
9
10
11
11 – power supply input 12Vdc
12 –button PRT (internal)
EZY-LAN 22.01-M:3.0-H:3b/4a/4b-F:3.1.14+
2
Wall mounting
The control panel is equipped with a wall
mounting bracket, which also integrates the
housing for the anti-removal tamper magnet.
1
2
3
PLEASE NOTE
4
The anti-removal tamper function is
available starting from the HW 4B version
5
6
13
14
To mount, proceed as follows:
1. Use the bracket as a template for the holes
2. Drill two 5mm diameter holes on the wall at the
points (13)
3. (IF TAMPER PROTECTION NECESSARY)
Make a 6mm diameter hole 20mm deep on the
wall at point (15)
4. Fix the wall bracket with the supplied plugs
through the holes (13)
5. (IF TAMPER PROTECTION NECESSARY)
Insert the magnet supplied in the appropriate
hole in the bracket (15)
6. Insert the control panel on the bracket
matching the slots on the bottom with the
appropriate supports (14), then move the
control panel downwards until it stops.
13 - holes for wall plugs
14 – control panel supports
15 - hole for magnet (optional)
13
15
14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EZY-LAN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duevi EZY-LAN

  • Page 1 EZY-LAN 22.01-M:3.0-H:3b/4a/4b-F:3.1.14+ EZY-LAN Wireless alarm panel with Ethernet + Wi-Fi + GSM + LTE Identification of the parts Wall mounting The control panel is equipped with a wall mounting bracket, which also integrates the housing for the anti-removal tamper magnet.
  • Page 2: Power Supply And Battery

    LED signals Power supply and battery The system status indication of the RGB LEDs (6) The control panel is powered by an external can be disabled in the programming. 12Vdc 2Ampere power supply to be connected to The intensity of the RGB LEDs (6) is reduced after the appropriate jack input (11).
  • Page 3: Manual Settings

    To enter the manual settings (virtual dip-switches) The control panel can be programmed only using proceed as follows: the dedicated application "DUEVI Connect", 1. With the control panel disarmed, press the available for Windows, IOS and Android systems. PRT button (12) for 3 seconds to enter the...
  • Page 4 11 Homepage (SETUP) Mode = <Router> In this mode the control unit uses its own Wi-Fi By pressing the ENTER IN SETUP button, the to connect to a Router/AP. control unit switches to programming mode and • Router SSID: name of the Wi-Fi router to the RGB LEDs of the control panel flash white.
  • Page 5: Wireless Devices

    Email Pressing the icon (gear) enter the device SMTP server settings that the control panel will settings, where you can change its properties use for sending emails. (they vary depending on the device). 12 Settings menu (SETUP) NOTE: Some devices can receive Firmware updates (eg control panel, The settings menu, accessible by pressing the wireless sirens, video-pir).
  • Page 6 Alert: enables / disables the bell sound the Shelly manual or to the numerous tutorials on (chime) on the zone at each detection the internet. when the sector is disarmed. The Shelly must have a fixed IP on the local VIDEO-PIR network (i.e.
  • Page 7 OUTPUTS MANAGEMENT • Low Alarm (L1) duration: duration of the low level alarm Shelly devices make the management of outputs • High Alarm (L2) duration: duration of the high available in the control panel. level alarm The outputs, like the zones, can be set within the •...
  • Page 8: Notifications (Setup)

    • ✓ Rolling shutter control - Can be used for: Allowed images: indicates which devices with Shelly 2.5 (shutter mode) video verification the user can see • Time limitation: [only for Normal user] enables Once the type of output control has been the user only within the time slots established selected, it is possible to select one or more in the selected time program...
  • Page 9 • • Tampering alarm: events (tampering Operation: defines what and when to be masking) that generate a tampering alarm executed by the control panel. It can be • executed: Panic alarm • An Action (among those already created) Silent alarm •...
  • Page 10 12.8 Logics (SETUP) Pressing the icon (gear) you enter the station settings, where you can change its properties. A logic is a rule that creates a cause-effect link • Sending events to the Monitoring Station: between a certain event and an operation (Action Activate / Deactivate or Scenario) that the control panel must perform •...
  • Page 11 13 Homepage (TEST) number of the pressed button, the operation associated with the button and the RSSI radio By pressing the ENTER TEST button, the control level received from the control panel. panel switches to test mode and the RGB LEDs Each new transmission will be placed at the top of of the control unit flash blue.
  • Page 12: Warnings And Precautions

    Hereby, DUEVI declares that the radio equipment type “Wireless alarm control panel with Ethernet / Wi-Fi / GSM / LTE connection” mod. EZY-LAN is in compliance with Directive RED 2014/53/EU. The full text of the EU Declaration of Conformity is available at the internet address www.duevi.eu...

Table of Contents