Duevi DIRRV2 Installation And Use Manual

Infrared wireless detector

Advertisement

DIRRV2
INFRARED WIRELESS DETECTOR
[SMD] [48bit] [SPV] [AN]
DO NOT USE OUTDOOR: THE DEVICE IS NOT PROTECTED AGAINST WEATHERING
REPLACE THE BATTERY ONLY WITH THE SAME MODEL. DO NOT DISPOSE THE BATTERY AS UNSORTED MUNICIPAL WASTE, USE THE
RELEVANT BOXES.

1. RECOMMENDATIONS

MOUNT AT ABOUT 240 CM HEIGHT, ON STABLE SURFACE, NON-METALLIC, FAR FROM HEATING SYSTEMS OR AIR FLOWS. DO NOT
MOUNT THE DETECTOR NEAR TO TRANSMITTERS, HEATING DUCTS AND/OR CONDITIONERS OR FACING TO WINDOWS EXPOSED TO
DIRECT SUN LIGHT.
BOTH JOINT (OPTIONAL) AND DETECTOR HAVE A DIRECTION OF ORIENTATION, WHICH MUST BE RESPECTED. AN ARROW ON THE REAR
SIDE OF JOINT AND DETECTOR INDICATES THIS DIRECTION. PLACE THEM IN WITH THE SAME ORIENTATION, WITH THE ARROW
POINTING UPWARD.
Anti-removal
tamper switch

2. INSTALLATION WITH JOINT (OPTIONAL)

1. Once defined the installation position, fix the joint (optional) on wall, verify the integrated tamper switch is closed, then fix it with the dowels
provided:
Screws for dowels
FASTEN THE INTERNAL JOINT LOCK SCREW AFTER TEST OF DETECTOR ORIENTATION
INSTALLATION AND USE MANUAL
Installation direction: arrow must
be pointing upward
Joint (rear side, optional)
Screw for joint lock
Detector (rear side)
Joint (optional)
15.03-M:8.2-H:SE-04v2-13
Dowels
Wall

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIRRV2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duevi DIRRV2

  • Page 1 DIRRV2 INFRARED WIRELESS DETECTOR [SMD] [48bit] [SPV] [AN] INSTALLATION AND USE MANUAL 15.03-M:8.2-H:SE-04v2-13 DO NOT USE OUTDOOR: THE DEVICE IS NOT PROTECTED AGAINST WEATHERING REPLACE THE BATTERY ONLY WITH THE SAME MODEL. DO NOT DISPOSE THE BATTERY AS UNSORTED MUNICIPAL WASTE, USE THE RELEVANT BOXES.
  • Page 2 2. Open the detector, remove the cover and unscrew the battery bracket 3. Make a 7 mm hole on frame and fix the detector to the joint, aligning the joint with the frame of the sensor and pass the cable inside: 4.
  • Page 3 3. TECHNICAL DIP1 Mode Normal Test 2 pulses 1 pulse DIP2 Pulse count (low sensitivity) (high sensitivity) DIP3 COVER Tamper Disabled Enabled DIP4 OPENED CLOSED J.TMP Anti-removal/Joint Tamper Enabled Disabled J.SPV Supervision POWER 9 V alkaline battery (mod. BAT9) FREQUENCY 433,92 MHz RADIO RANGE 100 m (open field)
  • Page 4 Test the detector (detection and radio range) placing it in the installation point.  After each sensitivity adjustment (acting on trimmer) wait some seconds the detector stabilization: • turn trimmer clockwise to increase sensitivity • turn trimmer counter clockwise to decrease the sensitivity When “pulse count”...