Duevi MOSKITO-AMR Installation And Use Manual

Wireless omni-directional outdoor infrared detector

Advertisement

Quick Links

MOSKITO-AMR
Wireless omni-directional outdoor infrared detector
MOSKITO is an outdoor sensor designed for the perimeter protection of a building with an efficiency never seen before: it int egrates
in the inside 6 passive infrared PIR heads.
MOSKITO
A double IR barrier on both sides of the sensor creates a protection of doors and windows in front of the building for a total length
of about 12 + 12 meters. Two additional IR heads, furthermore, guarantee the detection of approaching from frontal side up to 8
meters, avoiding potential elusion attempts of the lateral protection. The lateral protection on each side is made of two IR heads
working with AND logic, which create two curtain detection areas with an opening of 10° and range up to 12 meters each .
INSTALLATION AND USE MANUAL
15.08-M:3.0-H:SE-05v2-14-F:x.x

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MOSKITO-AMR and is the answer not in the manual?

Questions and answers

Summary of Contents for Duevi MOSKITO-AMR

  • Page 1 MOSKITO-AMR Wireless omni-directional outdoor infrared detector INSTALLATION AND USE MANUAL 15.08-M:3.0-H:SE-05v2-14-F:x.x MOSKITO is an outdoor sensor designed for the perimeter protection of a building with an efficiency never seen before: it int egrates in the inside 6 passive infrared PIR heads.
  • Page 2 RIGHT SIDE IR LEFT SIDE IR TOP VIEW FRONTAL IR The detection areas are independently adjustable each other, by geometry (lower PIR head orientable vertically), and by sensitivity (trimmer). On frontal side, instead, there is a volumetric detection area with 180° opening and range up to 8 m, with sensitivity adjustment (trimmer).
  • Page 3: Table Of Contents

    READ CAREFULLY THIS MANUAL BEFORE INSTALL YOUR NEW ALARM SYSTEM. KEEP THIS MANUAL FOR FUTURE REFERENCE. ONLY QUALIFIED TECHNICIAN MUST INSTALL THIS DEVICE. INSTALLER MUST FOLLOW CURRENT REGULATIONS. THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY IMPROPER USE OF THE PRODUCT, INCORRECT INSTALLATION OR FAILURE TO COMPLY WITH INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL SYSTEMS.
  • Page 4: Technical

    TECHNICAL MAINBOARD DIP 1 ÷ 12 - DIP switches for sensor functions Antenna J6 –Inclinometer tamper exclusion J5 - Exclude anti-removal tamper RV2 - Trimmer for RIGHT side range BUZZER adjustment RV3 - Trimmer for LEFT side range adjustment J4 - Exclude anti-opening tamper Battery connector TAMPER - Anti-opening FRONT BOARD...
  • Page 5 RIGHT BOARD LED – Right upper IR head detection (only in TEST mode) IR – Right upper IR head J2 – Jumper for range/sensitivity reduction of right upper head LED – Right lower IR head detection (only in TEST mode) IR –...
  • Page 6 BATTERY If the sensor is already powered, before proceed it is necessary to disconnect the battery, open the jumper J4 and hold the tamper switch for about 3 seconds: in this way the circuit will be completely discharged and will be possible to start-up the sensor correctly. To power the detector, insert two CR123A 3 V lithium battery type inside the battery-holder, respecting the polarity: Lithium battery Battery holder...
  • Page 7 Radio Range 100 m (open field) Events Right side alarm Left side alarm Front side alarm Masking alarm Elusion Low battery (LWB) Supervision Tamper Learning (AN) Compatibility See compatibility table at pag. 13, 14 Signals Detection LED * 6 red LEDs (one LED each IR head) Alarm LED * 1 blue LED for alarm Acoustic *...
  • Page 8: Precautions

    PRECAUTIONS Installation height must be between 100 cm and 140 cm. To obtain certain detection, the sensor must be installed so that the intruder crosses the IR zones. Th e detection range is reduced approaching towards the front of the sensor. Mount the sensor vertically, without front and side tilt.
  • Page 9 Do not install the detector in an environment with electromagnetic interference or vibrating objects Do not install the detector near to heating systems or air conditioner. It is recommended to install the detector at least 50 cm from the nearest gate.
  • Page 10: Detection Area

    DETECTION AREA Left and right detecting sides are 12 meters length range each, reaching 24 meters of linear protection, with 10° opening ang le on horizontal plane. FRONT VIEW LEFT SIDE RIGHT SIDE Adjustable lower IR heads TOP VIEW RIGHT SIDE LEFT SIDE FRONT SIDE Temperature: 21 °C...
  • Page 11: Settings

    SETTINGS DIP SWITCH ANTI-MASKING ON/OFF (DIP1) The anti-masking system protects 24h/24 the sensor against attempts to cover it (blinding) in order to prevent the detection of violations. The anti-masking cannot work properly without the cover on the sensor. DIP1 = OFF Anti-masking disabled: no anti-masking protection DIP1 = ON Anti-masking disabled: the sensor sends the radio MASK alarm in case of masking attempts (cover the sensor to...
  • Page 12: Anti-Elusion On/Off (Dip2)

    ANTI-ELUSION ON/OFF (DIP2) DIP2 = OFF Anti-elusion disabled: the sensor generates alarm if both IR heads of any side (left, right, front) detect. DIP2 = ON Anti-elusion disabled: the sensor generates alarm if both IR heads of left or right sides detect (as in NORMAL mode) Furthermore, alarm is generated if both front IR heads detect and then any single IR head of left or right sides detect SIDES ADJUSTMENT (DIP3, DIP4, DIP5) Select which side to adjust / perform walk test using DIP3, 4 and 5.
  • Page 13: Side Exclusion (Dip10, Dip11)

    SIDE EXCLUSION (DIP10, DIP11) Select if always exclude one or more sides (the two heads of the side) of the detector, so to avoid false alarms from a certa in side. DIP10 DIP11 All sides of the detector are always active (NORMAL or ANTI-ELUSION mode) The left side is always excluded (NORMAL or ANTI-ELUSION mode) The right side is always excluded (NORMAL or ANTI-ELUSION mode) DIP2 = OFF (anti-elusion OFF)
  • Page 14: Supervision (Dip12)

    “OLD” receivers “NEW” receivers RX808 RX808-LCD RX40 RX2AP RX2AP SUPERVISION (DIP12) DIP12 = ON Enable the supervision (in life) radio code sending This code is sent every 60 minutes from last event. At each event, the counter resets the timeout to 60 minutes DIP12 = OFF Disable the supervision (in life) radio code sending...
  • Page 15: Walk Test

    WALK TEST DIP7 = ON Sensor in TEST mode: ALARM LED enabled DIP3 = OFF DIP10 = OFF DIP4 = OFF Walk-test on all sides All sides active DIP11 = OFF DIP5 = OFF In this mode, walking in front of or side to the sensor, each time any IR head detects intrusion the combined LED switch on. UPPER LEFT head detection LED UPPER FRONT head detection LED UPPER RIGHT head detection LED...
  • Page 16: Sensitivity/Range Adjustment

    SENSITIVITY/RANGE ADJUSTMENT DIP7 = ON DIP 10, 11 = OFF THE DETECTOR ENTER IN ADJUSTMENT MODE: ALL THE CHANGES ARE IMMEDIATELY APPLIED, THE VALUE OF TRIMMERS IS READ AND THE IR HEAD LEDS ARE ENABLED. TO HAVE THE ACOUSTIC SIGNALLINGS FROM BUZZER SET DIP6 TO ON. TO CHECK THE REAL RANGE OBTAINED, ALWAYS PLACE THE COVER OVER THE SENSOR AFTER EACH ADJUSTMENT.
  • Page 17 EACH SIDE HAS A JUMPER (SEE NEXT FIGURE) TO REDUCE THE RANGE AND SENSITIVITY OF UPPER HEADS. FRONT SIDE FRONT upper head range reduction LEFT upper head range RIGHT upper head range reduction reduction LEFT SIDE RIGHT SIDE WHEN THE JUMPER IS CLOSED, THE RANGE AND SENSITIVITY OF THE UPPER HEAD ARE REDUCED AT ABOUT 50% OF MAXIMUM VALUE (THE MAX VALUE DEPENDS FROM TRIMMER REGULATION).
  • Page 18: Lower Lateral Ir Heads Inclination

    LOWER LATERAL IR HEADS INCLINATION The lateral heads inclination allows to adjust the range and depends on the sensor installation height. The adjustment has three steps (3 positions) according to the following scheme, acting on combined pins. IT IS POSSIBLE TO ADJUST THE TWO SIDE DIFFERENTLY...
  • Page 19: Range Adjustment Of Lateral Ir Heads (Rv2 And Rv3 Trimmer)

    TEST AFTER EACH ADJUSTMENT! RANGE ADJUSTMENT OF LATERAL IR HEADS (RV2 AND RV3 TRIMMER) Side trimmer position Range with head in position 1 Range with head in position 3 (RV2 and RV3) about 12 m about 3 m MAX RANGE about 6 m about 1,5 m MIN RANGE...
  • Page 20: Front Side Adjustment

    FRONT SIDE ADJUSTMENT DIP7 = ON Sensor in TEST mode: ALARM LED enabled DIP3 = ON DIP4 = OFF Walk-test only for front side DIP5 = OFF ATTENTION! If DIP10 = ON and DIP11 = ON the front side is excluded Adjust the range using the RV1 trimmer (this trimmer adjust contemporary the sensitivity of both upper and lower IR heads).
  • Page 21: Right Side Adjustment

    RIGHT SIDE ADJUSTMENT DIP7 = ON Sensor in TEST mode: ALARM LED enabled DIP3 = OFF DIP4 = ON Walk-test only for right side DIP5 = OFF ATTENTION! If DIP10 = ON and DIP11 = OFF the right side is excluded Adjust the range using the RV2 trimmer (this trimmer adjust contemporary the sensitivity of both upper and lower IR heads).
  • Page 22: Learning

    LEARNING AN LEARNING DIP7 = ON Sensor in TEST mode: ALARM LEDs active J4 = OPENED Anti-opening tamper enabled DIP6 = ON Buzzer enabled J5 = CLOSED Anti-removal tamper disabled DIP9 = OFF NEW radio codes J6 = CLOSED Inclinometer tamper disabled Power the detector Wait until the sensor ends its start-up phase.
  • Page 23: Tamper

    TAMPER The sensor is protected against tampering attempts by two controls: cover anti-opening and anti-removal (this one uses both inclinometer and electro-mechanic technologies). When the sensor is in TEST mode, a tamper event is signalled by 5 slow “beeps” sequence and blue alarm LE D (buzzer must be enabled, set DIP6 = ON).
  • Page 24 This device meets the R&TTE requirements (European Union) This manual may be subject to change without notice MADE IN ITALY...

Table of Contents