Introduction; Brief Introduction; Intended Use; Measurement Principle - Henry Schein MD300K2 Instructions For Use Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

1 INTRODUCTION

1.1 Brief Introduction

Thank you for purchasing the MD300K2 pulse oximeter. The main functions of the device include SpO , PR
and PI (Perfusion Index) measurements, visual and audible indication, probe o and finger out indicarion,
data storage, transmitting and review etc. Please read this manual carefully before using the device.
Notes:
• The illustrations applied in the manual may di er slightly from the actual device.
• The device is designed of handheld structure, please be sure not to turn upside down when using it.

1.2 Intended Use

The MD300K2 Pulse Oximeter is intended for continuous monitoring, spot-checking of oxygen saturation
(SpO ), pulse rate (PR) and PI (Perfusion Index) of single adult, adolescent, child and infant patients in
hospitals and clinics.

1.3 Measurement Principle

Principle of the oximeter is as follows: A mathematical formula is established making use of Lambert Beer
Law according to Spectrum Absorption Characteristics of Reductive hemoglobin(RHb) and Oxyhemoglobin
(HbO ) in red and near-infrared zones. Operation principle of the instrument: Photoelectric Oxyhemoglobin
Inspection Technology is adopted in accordance with Capacity Pulse Scanning and Recording Technology,
so that two beams of di erent wavelength of lights (660nm red and 905nm near infrared light) can be
focused onto a human nail tip through a clamping finger-type sensor. A measured signal obtained by a
photosensitive element, will be shown on the oximeter's display through process in electronic circuits and
microprocessor.
Diagram of Operation Principle
1. Red and Infrared-ray Emission Tube
2. Red and Infrared-ray Receipt Tube

1.4 Safety Information

Conception of Warning, Caution and Note
The Warning, caution and Note at this document are special information in favor of users operation.
Warning - Information concerning something that could possibly hurt the patient or operator.
Caution - Reminds the user to pay close attention to device operation, failure of which may cause abnormal
function of the instrument.
Note - Informs the user of other important information by suggestion, requirement and supplement.
Warnings!
1. Before use, carefully read the manual. This device is intended for use by persons trained in professional
health care. Our company will assume no warranty for using this equipment improperly.
2. Operation of the handheld pulse oximeter may be a ected by the use of an electrosurgical unit (ESU).
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

900-8275

Table of Contents