General - Carrier 40VMW005 Installation And Maintenance Instructions Manual

High wall indoor unit for variable refrigerant flow (vrf) systems
Table of Contents

Advertisement

CAUTION
DO NOT re-use compressor oil or any oil that has been
exposed to the atmosphere. Dispose of oil per local codes
and regulations. DO NOT leave refrigerant system open to
air any longer than the actual time required to service the
equipment. Seal circuits being serviced and charge with
dry nitrogen to prevent oil contamination when timely
repairs cannot be completed. Failure to follow these
procedures may result in damage to equipment. For
information about replacement oil type and viscosity, see
the Installation, Start-Up, and Service Instructions for the
38VMAH and 38VMAR outdoor units.
UNIT 40VMW
POWER SUPPLY (V-Ph-Hz)
TOTAL COOLING CAPACITY (Btuh)
SENSIBLE COOLING CAPACITY (Btuh)
HEATING CAPACITY (Btuh)
INDOOR FAN MOTOR
Type
Input (W)
INDOOR COIL
Number of Rows
Fin Spacing (fins/in.)
Fin Type
Tube Diameter, OD (in.)
Tube Type
Number of Circuits
INDOOR AIRFLOW (cfm)
Low
Medium
High
INDOOR NOISE LEVEL (dBA)
Low
Medium
High
UNIT
Unit Dimensions W x H x D (in.)
Packing Dimensions W x H x D (in.)
Net/Gross Weight (lb)
REFRIGERANT TYPE
EXPANSION DEVICE
DESIGN PRESSURE, H/L (psig)
REFRIGERANT PIPING (in.)
Liquid Side, OD
Suction Side, OD
CONNECTING WIRING
Power Wiring
Signal Wiring
DRAINAGE WATER PIPE DIAMETER, OD (in.)
LEGEND
AWG — American Wire Gage
EEV
— Electronic Expansion Valve
NEC
— National Electrical Code

GENERAL

The 40VMW high wall mount unit provides an efficient way to
heat or cool a space and an attractive appearance. The
equipment is initially protected under manufacturer's standard
warranty; however, warranty is provided under the condition
that the steps outlined in this manual for initial inspection,
proper installation, regular periodic maintenance, and everyday
operation of the unit be followed in detail. This manual should
be fully reviewed in advance before initial installation, start-up,
and any maintenance. Contact your local sales representative
or the factory with any questions BEFORE proceeding.
Table 1 lists physical data for each unit size. See Fig. 1 for
model number nomenclature. Figures 2 and 3 show unit
dimensions. Table 2 shows components that may or may not be
used for a particular installation.
Table 1 — 40VMW Physical Data
005
007
009
5,000
7,500
9,500
4,060
5,640
6,520
6,000
8,500
10,900
11
25
25
3
245
245
245
270
245
320
31.7
31.2
31.8
31.7
32.2
32.6
31.7
34.0
34.5
36 x 11-3/8 x 9
40-1/8 x 15-3/8 x 12-3/8
28/35
/
1
4
/
1
2
Sized per NEC and Local Codes Based on Nameplate Electrical Data
2-Core Stranded Shielded Cable 18 AWG
2
012
015
018
208/230-1-60
12,000
15,000
18,000
7,930
10,140
12,040
13,500
17,000
21,000
DC Motor
30
35
45
2
17
Hydrophilic Aluminum
0.276
Inner Groove
4
440
250
380
470
280
420
560
360
480
38.9
32.8
38.4
40.2
34.6
39.6
41.8
36.4
41.7
42-1/4 x 12-3/8 x 9
46-1/2 x 17-1/8 x 12-7/8
32/40.5
R-410A
EEV
580/320
/
NPT
3
4
024
030
24,000
30,000
15,330
18,950
27,000
34,000
75
85
20
5
460
480
530
600
650
770
36.8
38.1
42.0
43.6
43.2
48.3
47 x 13-1/2 x 10-1/8
50-3/4 x 15-1/8 x 18-1/8
38/50.5
/
3
8
/
5
8