Warranty

Fault
No D+ signal when
the engine is running
and red LED blinking.
No D+ signal when
the engine is running
and green LED blink-
ing.
12
Warranty
The statutory warranty period applies. If the product is defective, please contact your retailer or the
manufacturer's branch in your country (see dometic.com/dealer).
For repair and warranty processing, please include the following documents when you send in the
product:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
Note that self-repair or nonprofessional repair can have safety consequences and might void the
warranty.
13

Disposal

Recycling products with non-replaceable batteries, rechargeable batteries or light
sources
➤ If the product contains any non-replaceable batteries, rechargeable batteries or
light sources, you don't have to remove them before disposal.
➤ If you wish to finally dispose of the product, ask your local recycling center or spe-
cialist dealer for details about how to do this in accordance with the applicable dis-
posal regulations.
➤ The product can be disposed free of charge.
Recycling packaging material
➤ Place the packaging material in the appropriate recycling waste bins wherever pos-
sible.
12
Possible cause
Device is not mounted
correctly.
Voltage detection on
and the battery voltage
not reached the activa-
tion value.
Output signal exceeded
the 0.3 A load.
Device internal dam-
aged.
Solution
See chapter "Installing the device" on
page 9.
Wait for the battery voltage reach the acti-
vation value or turn off the voltage detec-
tion.
Remove the too high load from the output.
Wait 5 min. to reset.
Replace the device or send it in for repair.