Download Print this page

Seav BeSAFE RX Series Quick Start Manual

Single­channel receiver

Advertisement

Quick Links

BeSAFE RX S
INGLE
The BeSAFE RX radio receiver is designed for the remote operation of 
electrical and electronic equipment in conjunction with one or more 
SEAV radio­controls and/or transponders (BeSAFE Card, BeSAFE Key).
­ Mod. (BeSAFE RX 30,875):
­ Mod. (BeSAFE RX 306):
­ Mod. (BeSAFE RX 310):
­ Mod. (BeSAFE RX 418):
­ Mod.  BeSAFE RX 433 :
­ Mod.  BeSAFE RX 868 :
(  ) This product is destined for countries in which use is consented.
T
 
ECHNICAL
DATA
­ Power supply:
­ Max consumption:
­ Op. radio­controls:
­ Op. transponders:
­ Stored codes:
­ 1 (one) command relay:
­ Working temperature:
­ Dimensions:
­ Container:
­ Protection degree:
­ Radio­control range in open spaces:
C
 
 T
 
ONNECTION
OF
ERMINAL
BOARDS
CN1:          1   : 24 VAC/DC power supply input.
                   2   : 0 V power supply input.
                   3   : 12 VAC/DC power supply input.
                   4   : Clean command contact output.
                   5   : Clean command contact output. 
                   6   : Earth input.
                   7   : Antenna hot pole input.
CN2: Connection for Transponder 1 Reader (BeSAFE Reader ).
CN3: Connection for Transponder 2 Reader (BeSAFE Reader ).
CN4: Connection for PC "SW 2189" interface.
CN5: Normally open or closed command contact selection.
R
 I
ECEIVER
NSTALLATION
For the optimal operation between transmitter and receiver, we recom­
mend you choose the  point  of  installation carefully.  The  range  is  not 
merely linked to the technical features of the device itself, but it actually 
varies according to the radioelectric conditions of the area.
The receiver is fitted with an antenna consisting of a rigid wire section. 
Should you wish to increase the device sensitivity, you can connect a 
tuned   antenna   using   a   RG58   50   OHM   coaxial   cable.   The   antenna 
should be  placed  on the  exterior   in  a visible  position away   from  any 
metallic structures.
The installation of two receivers placed less than 5 metres from one an­
other is not possible.
­
 R
 
CHANNEL
ECEIVER
30,875 MHz
306
310
418
433,92 MHz
868,3
12­24VAC­DC
12­18 Bit or Rolling Code
Card or Key­ring
­10 C ÷ 55 C
110x121x47 mm
ABS (UL94V­0)
30­70 metres
GB
O
 
PERATION
WITH
The   receiver   can   be   combined   with   SEAV   radio­controls   and/or 
transponders  and  is   designed  to  store  up  to  500  different   users.  We 
therefore recommend you make a note of the "memory position ­ user 
name" correspondence in the form provided. For use with radio­controls, 
the receiver is fitted with an incorporated receiver.  For use with "Be­
MHz
SAFE CARD and  BeSAFE KEY"  transponders, the connection  of 
MHz
one or two "BeSAFE Reader" proximity readers supplied as option­
MHz
als will be necessary. 
MHz
P
 R
ROGRAMMING
The programming of radio­controls and/or transponders is self­learning, 
as follows.
Use   the   UP   or   DOWN   keys   to   go   to   the   desired   memory   position 
(viewed on the display from 001 to 500), paying attention to the TRANS­
4.5 W
MITTER and TRANSPONDER LEDS, as one of them turning on means 
the   location   is   busy.   Press   the   SEL   key,   the   TRANSMITTER   and 
TRANSPONDER   LEDS   will   begin   to   flash,   and   meanwhile   send   the 
500 Max
code with the radio­control or bring the transponder closer to the "Be­
30VDC 1A 
SAFE Reader" proximity reader, (the display will indicate  STO  stored), 
the TRANSMITTER or TRANSPONDER LED will go from off to on and 
programming is thus complete.
To delete a radio­control or transponder stored previously, use the UP or 
IP54
DOWN keys to go to the memory location that is busy, press the SEL 
key, the TRANSMITTER  or  TRANSPONDER LED will begin to flash; 
press the SET key (the display will indicate "DEL" deleted), the LED will 
go from on to off and delete is thus complete.
During normal operation, the display panel indicates the memory loca­
tion of the device stored previously currently in use.
R
 P
APID
ROGRAMMING
The rapid programming of radio­controls and/or transponders is only al­
lowed when all the receiver memory is free. To make sure that all the 
memory is free, follow the Reset procedure.
Rapid programming means you do not have to select a new memory loc­
ation for another radio­control and/or transponder every time, but start­
ing   from   position  001,   the   control   unit   automatically   increases   the 
memory location and remains on standby for 10 seconds, from the input 
of a new radio­control and/or transponder to store.
P
ASSWORD
Once   you   have   finished   programming   the   radio­controls   and/or 
transponders, you can store a password in the PAS position, to disable 
and enable receiver programming, as follows.
Use the UP or DOWN keys to go to the PAS memory position, press the 
SEL key, the TRANSMITTER and TRANSPONDER LEDS will begin to 
flash,   and  meanwhile  use   the  UP  or   DOWN  key   to  select   a  number 
between   001   and   500,   press   the   SET   key,   (the   display   will   indicate 
"CLO" closed), and the TRANSMITTER and TRANSPONDER LEDS will 
go from off to on.
To re­enable programming, use the UP or DOWN keys to go to the PAS 
memory   position,   press   the   SEL   key,   the   TRANSMITTER   and 
TRANSPONDER LEDS will begin to flash, meanwhile use the  UP or 
DOWN keys   to select  the key   number  selected previously, press  the 
SET key, (the display will indicate OPE open).
To   delete   a   password   (operation   only   allowed   if   the   system   is   open 
OPE), use the UP or DOWN keys to go to the  PAS  memory position, 
press the SEL key, the TRANSMITTER and TRANSPONDER LEDS will 
begin to flash and meanwhile press the SET key (the display will indicate 
DEL  deleted), the TRANSMITTER and TRANSPONDER LEDS will go 
from on to off.
N.B.: if you enter an incorrect password, you will have to wait 5 minutes 
to repeat the operation, and if you enter another incorrect password, you  
will have to wait 1 hour.
R
ESET
If it is appropriate for the factory configuration to be restored (operation 
only allowed if the system is open OPE), press the SEL and SET keys 
simultaneously, and the LEDS will turn off, and the display will indicate 
the PAS position.
N.B.:  the display is turned off after one minute of inactivity to save en­
ergy.
1
 R
­
 
/
 T
ADIO
CONTROLS
AND
OR
RANSPONDERS
­
 
/
 T
ADIO
CONTROLS
AND
OR
RANSPONDERS
 
 R
­
 
OF
ADIO
CONTROLS
AND
/
 T
OR
RANSPONDERS
Rev. 1.2  03/07

Advertisement

loading
Need help?

Need help?

Do you have a question about the BeSAFE RX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seav BeSAFE RX Series

  • Page 1 PERATION WITH ADIO CONTROLS RANSPONDERS The   receiver   can   be   combined   with   SEAV   radio­controls   and/or  The BeSAFE RX radio receiver is designed for the remote operation of  transponders  and  is   designed  to  store  up  to  500  different   users.  We  electrical and electronic equipment in conjunction with one or more  therefore recommend you make a note of the “memory position ­ user  SEAV radio­controls and/or transponders (BeSAFE Card, BeSAFE Key).
  • Page 2  F  V  PC C URTHER UNCTIONS ONNECTION The receiver can be connected to a Personal Computer through the use  of a “SW 2189” package supplied as an optional, thanks to which you  may access further functions.      I  ­  NSTALLER IMPORTANT − All operations requiring the opening of the casing    (such as installation, programming and repair, etc.) must be       carried out by skilled staff only. − The fixing of power supply leads and connection cables must be   secured through the use of cable clamps. SEAV s.r.l. hereby declares that the product below: BeSAFE RX Single­channel Receiver complies with the re­ quirements of Directive R&TTE 99/5/EC.   Rev. 1.2  03/07...

This manual is also suitable for:

Besafe rx 30,87Besafe rx 306Besafe rx 310Besafe rx 418Besafe rx 433Besafe rx 868