Download Print this page

Controls And Adjustments - Flowmetrics PA-1001A Series Manual

Signal conditioner & convertors

Advertisement

STANDARD PRE-AMPLIFIER ADJUSTMENTS:
CARRIER ADJUSTMENT:
RF TRIGGER:
MAG TRIGGER:
COIL SELECTION:
LIN\RAW PULSE:
PULSE SELECTION:
PULSE SCALING ADJUSTMENTS:
PULSE SCALER:
PA1001A – 7/02

CONTROLS AND ADJUSTMENTS:

A twenty turn control used to precisely tune the specific sensing
depth, wall thickness, material type, air gap,
etc. of the RF pickup coil.
A twenty turn control used to set the trigger level of the
RF coil input above the ambient noise level.
A twenty turn control used to set the trigger level of the
Magnetic coil input above the ambient noise level.
A two-position jumper that is used to select the desired
pickup coils to be used as the input.
Input Coil Type
RF
Magnetic
A two-position jumper that is used to select the desired
Pulse train.
Pulse Type
Raw pulse train
Linearized pulse train
(NOT AVAILABLE YET)
A four-position jumper that is used to select the
Desired type of pulse output.
Pulse Output Type
Open Collector
Square Wave to Vin
TTL/CMOS
0-10 VDC Square Wave
A 8 position jumper header located on PA1001 circuit board which is
used in programming the desired pulse output scaling (Division of 1,
2, 4, 8, 16, 32, 64, or 128). Factory set with division of 1 as standard.
Page 8 of 11
HD2 Setting
RF
MAG
JP1 Setting
RAW
LIN
HD1 Jumper Settings
JP2
JP1 and JP2
JP1, JP2 and JP3
JP1, JP2 and JP4

Advertisement

loading