Trotec TRH 20 E Operating Manual

Trotec TRH 20 E Operating Manual

Oil-filled radiator
Hide thumbs Also See for TRH 20 E:

Advertisement

Quick Links

TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E
EN
OPERATING MANUAL
OIL-FILLED RADIATOR
EN This product is only suitable for well
insulated spaces or occasional use.

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TRH 20 E

  • Page 1 TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E OPERATING MANUAL OIL-FILLED RADIATOR EN This product is only suitable for well insulated spaces or occasional use.
  • Page 2: Table Of Contents

    Follow the manual without supervision. Information marked with this symbol indicates that the operating manual must be observed. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 3 • The mains connection must correspond to the specifications in the Technical annex. • Insert the mains plug into a properly fused mains socket. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 4 Warning Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 5: Information About The Device

    The device can again be used as usual only a few seconds after placing it back in vertical position and on solid ground. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 6 Cable winder (TRH 22 E / TRH 23 E with plug holder) Foot with castors Air inlet (blower) Air outlet (blower) Flip switch (blower) oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 7: Transport And Storage

    • Place no further devices or objects on top of the device to prevent it from being damaged. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 8 4. Position the respective U‑bolt between either the first or the last two ribs at the device bottom. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 9 5. Turn the device over and set it down on the castors. If necessary, use a spirit level to check the correct positioning. Adjust the screw connection if required. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 10: Operation

    • Make sure that the power cable is guided along the back of the device. Never guide the power cable along the front of the device! oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 11 (performance with fan): 2,900 W TRH 24 E level 1: 1,000 W level 2: 1,200 W level 3: 2,200 W Operating control lamp oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 12: Errors And Faults

    • The room thermostat might be defective. Have a defective room thermostat replaced by a specialist electrical company. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 13: Maintenance

    Wipe the housing dry after cleaning. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 14: Technical Annex

    100 cm front (D): 100 cm 100 cm 100 cm 100 cm 100 cm Weight 7 kg 8 kg 8.5 kg 10 kg 9.5 kg oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 15 With working time limitation With black bulb sensor Contact details Trotec GmbH Grebbener Straße 7 D-52525 Heinsberg NA: not applicable oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 16: Disposal

    Regulations 2013 (2013/3113) power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly manner. oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E / TRH 24 E...
  • Page 17 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

Trh 21 eTrh 22 eTrh 23 eTrh 24 e

Table of Contents