Page 1
412606 Indicator Instruction Manual Contents subject to change without notice Version 1.0 Issue AA 412606 www.globalindustrial.com...
Page 2
(check with 411 in your area for "scale dealers") and have them perform this task. This work is not covered by any warranty. 412606 www.globalindustrial.com...
Page 3
Connect the new indicator to the scale base Run the cable through the pole, plug the metal female connector from indicator to the male connector from scale base. 412606 www.globalindustrial.com...
Page 4
Then put on the weight that you selected and press the TARE button to confirm. 5. The calibration is completed and the indicator will be restart, please remove the weight from the platform. 412606 www.globalindustrial.com...
Page 5
Note: If an error has occurred, the scale will display “CAL. Er” and return back to step 4 for re-calibration. 6. Check the calibration by putting the weight that you calibrated at back on the scale, if it is off repeat the calibration process again. 412606 www.globalindustrial.com...