Pre-Lighting Instructions: Connecting the LP Cylinder
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
– Turn heater gas valve knob and LP cylinder valve to OFF position.
– LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS. Turn fitting CLOCKWISE to loosen.
Protect this fitting when disconnected from LP cylinder.
– Have your LP cylinder filled by your local propane gas supplier.
– Some LP cylinders have a bleed-OFF valve. This valve should be inspected for leaks after each filling of the LP
cylinder. Turn the valve clockwise to close.
– Fasten full propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE.
– With heater gas valve knob still in OFF position turn ON the LP cylinder valve and check for leaks with soap solution.
WARNING
Purging and filling of the LP cylinders must be performed by personnel who have been thoroughly trained in accepted
LP gas industry procedures. Failure to follow these instructions may result in explosion, fire, severe personal injury or
death.
Checking For Leaks
– To check for leaks, make up a 50/50 solution of dish soap and water. Apply this solution to all gas connections. If
bubbles appear, there is a leak. If a leak is found, turn off the gas supply, and re-connect the leaking connection. If the
leak persists after several tries, contact Gasland Customer Service at 1 (844) 538-7890.
– The installation of this heater must meet all local codes and/or gas utility requirements. In the absence of local codes,
the National Fuel Code ANSI Z223.1 should be followed.
– The minimum clearances to any combustible construction materials must be maintained at all times (See Page 3).
– Inspect the heater before each use, and at least annually by a qualified service person.
WARNING
EXTREMELY HOTduring operation. Do Not touch any metal components while in operation. Keep gasoline and any
other flammable liquids away from the heater.
Lighting Instructions:
1. STOP! Read all of the safety information provided with this heater.
2. Turn valve on propane cylinder COUNTERCLOCKWISE until fully open.
3. Wait five (5) minutes for any gas to clear. Smell for gas. If none is evident, proceed to the next step.
4. Push in the valve knob and turn to "PILOT".
Note: If this is first time use for heater or LP cylinder has been replaced, hold the valve knob for approximately 30
seconds to allow bleeding of air from system then turn valve knob to PILOT.