Specifications - GASLAND chef MHA18B Installation Instructions Manual

Cabinet heater
Table of Contents

Advertisement

Available languages

Available languages

USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO2
NO2
WARNING
For use with propane (LP) gas only.
– ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.
– Use heater in accordance with all local codes and with CSA 5.90 U.S. (5th Ed.) Infrared Patio Heater.
– This heater is shipped from the factory for use with propane (LP) gas only. Do not convert to any other gas. Installation
must conform to local codes, or in their absence, with the standard for the Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1.
– Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame to check for
gas leaks.
– Use only the regulator and hose assembly provided with this heater. Inspect the regulator/hose assembly prior to each
use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with the proper assembly shown in
the parts list, prior to using the heater. The replacement hose assembly should follow manufacturer's specification.
– This heater is not for use on finished floors.
WARNING
The hose assembly shall be protected from traffic, building material and contact with hot surfaces both during use and
while in storage.
WARNING
RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!

Specifications

Model
BTU
Fuel Consumption (lb./hr)
Heat Settings
Maximum Operating Hours
Required Cylinder Lbs.
Fuel Type
Heating Area (Ft.
1 (844) 538-7890
support@gaslandchef.com
5 ppm
Minimum and Maximum Inlet Pressure
Model
Min.
Max.
Use ONLY 20 lb. LP Gas Cylinder: 18" x 12.25"
)
2
Canada STEL (15 minutes Reg 833/1 hour
WSBC) WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
CO
100 ppm
15000 ppm (WSBC)
CO2
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
NO2
5.0 ppm (Reg 833)
MHA18B
5 PSI
Bottle Pressure
MHA18B
6,000 / 12,000 / 18,000
0.29 /0.57 / 0.86
3
69 / 35 / 23
20
150 / 300 / 450
www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
04

Advertisement