Problem
Burner fails to ignite
No spark created when
ignited
Heater stops running by
itself

Exploded View

1 (844) 538-7890
support@gaslandchef.com
Possible Cause
1. Air in gas line
2. Gas pressure from cylinder too low.
3. LP cylinder valve turned off
4. Obstruction in air passageway.
5. Dirt in pilot orifice.
6. Safety switch in cylinder valve
engaged.
7. Tipover switch engaged.
1. Incorrect igniter electrode position.
2. Electrode damaged or broken.
3. Loose or disconnected igniter wire.
4. Broken igniter wire.
1. Thermocouple damaged
2. Gas control valve damaged.
3. Gas leak
4. Thermocouple not in contact with
pilot flame.
5. Tip-over switch damaged, or loose
connection at tipswitch.
6. Out of fuel.
Solution
1. Keep depressing the gas control knob for at
least 30 seconds to remove any in line.
2. Check LP cylinder pressure. Tank may be
empty.
3. Open LP cylinder valve.
4. Inspect and clean heater housing.
5. Blow out, or clean pilot orifice.
6. Close LP cylinder valve. Wait 1 min. for switch
to click off. Reopen LP cylinder valve slowly.
7. Move heater to a level surface.
1. Properly position electrode
2. Replace the electrode.
3. Tighten or reconnect loose wire.
4. Replace igniter wire.
1. Replace entire heater
2. Replace gas control valve.
3. Check all connections for leaks using 50/50
solution of dish soap and water. Repair any
leaks found.
4. Clean inside of heater housing.
5. Inspect tip-over switch and connections.
Replace if necessary.
6. Replace LP cylinder