Ebyte E78-868LN22S User Manual page 25

Lorawan wireless module
Hide thumbs Also See for E78-868LN22S:
Table of Contents

Advertisement

E78-864LN22S
Command
character
CRXP
(Set the receive
window
parameters)
+CLINKCHECK:Y0, Y1, Y2, Y3, Y4
YO indicates the Link Check result:
0 - indicates that the Link Check is successfully executed.
Not 0 - indicates that the Link Check execution failed.
Y1 is DemodMargin
Y2 is NbGateways
Y3 is the downstream RSSI
Y4 is the downstream SNR
Return
<value>: Enable control for Link Check
value
0 – Link Check is not enabled
description
1 – Perform a Link Check
2 - The module automatically carries the linkcheck command in each
upstream packet.
Return OK, the setting is successful.
If X1=1, after waiting for a while, it will return the second response message
in the following format:
+CLINKCHECK:Y0, Y1, Y2, Y3, Y4
YO indicates the Link Check result:
0 - indicates that the Link Check is successfully executed.
Not 0 - indicates that the Link Check execution failed.
Example
Y1 is DemodMargin
Y2 is NbGateways
Y3 is the downstream RSSI
Y4 is the downstream SNR
AT+CLINKCHECK=1
OK
+CLINKCHECK: 0, 0, 1, -68, 8
Precautions
Need to set before sending data
Command
Command Format
Type
Test
AT+CRXP=?
command
Setting
AT+CRXP?
command
AT+CRXP=<RX1DRoffest>,<
Parameter
RX2DataRate>,<RX2Frequenc
Description
y>
Return
<RX1DRoffest>,<RX2DataRate>,<RX2Frequency> See the Lorawan
value
protocol for details.
description
response
+CRXP:"RX1DRoffest","RX2DataRate
","RX2Frequency"
OK
+CRXP:<RX1DRoffest>,<RX2DataRate
>,<RX2Frequency>
OK
OK
25