E78-864LN22S
Command
character
CRM
(Set reporting
mode)
Precautions
Need to set before sending data
Command
Command Format
Type
Test
AT+CRM=?
command
Query
AT+CRM?
command
AT+CTXP=<reportMode>,[rep
Setting
ortInterval]
command
<reportMode>:
0- acyclic reporting data;
1- Periodic reporting of data;
<reportInterval>: This parameter is only available when data is reported
periodically. Time interval of periodic report data, unit: s.For different Dr's,
the minimum period allowed is different. The definition of period level is
adopted, as shown in the following table.
Parameter
Rate\cycle(s)\level
Description
DR0
DR1
DR2
DR3
DR4
DR5
Return
<reportMode>:
value
0- acyclic reporting data;
description
2- Periodic reporting of data;
<reportInterval>: This parameter is only available when data is reported
periodically. Time interval of periodic report data, unit: s.For different Dr's,
the minimum period allowed is different. The definition of period level is
adopted, as shown in the following table.
Rate\cycle(s)\level
DR0
DR1
Example
DR2
DR3
DR4
DR5
AT+CRM=1,10
OK
Precautions
Need to set before sending data
response
+CRM:"reportMode","reportInterval"
OK
+CTXP:<reportMode>,[reportInterval]
OK
OK
LV1
LV2
150
300
75
150
35
70
15
30
10
20
5
10
LV1
LV2
150
300
75
150
35
70
15
30
10
20
5
10