RAS+DL (on its display). By programming the sensor, display of values and symbols can be customized. Moreover, there is a choice between automatic or manual scrolling through displays.
Access to the programming level is only possible with the slider switch set to the „Standby“ po- sition (leftmost). RAS+DL can the configured using the key and the set up to display further values. The following symbols are used in the menu descriptions to differentiate between long and short key...
Menu – general overview The displayed menu options are matched to the respective controller types: Menu overview for UVR16x2, RSM610, CAN-I/O45 and UVR1611 General sensor settings are adjusted in the menu section „CONFIG“. Values and symbols to displayed are selected in the menu section „VALUES“. V 1 10 = Sensor version number...
Page 7
Menu overview for ESR21 (min. version 5.0) and ESR31, UVR61-3 (min. version 8.3), UVR63 (min. version 1.5) General sensor settings are adjusted in the menu section „CONFIG“. Values and symbols to displayed are selected in the menu section „VALUES“. V 1 10 = Sensor version number...
Menu overview of all other controllers General sensor settings are adjusted in the menu section „CONFIG“. Values and symbols to displayed are selected in the menu section „VALUES“. The menu option „POWER“* (heat meter) is only displayed for controllers that have this functionality. V 1 10 = Sensor version number...
Switching between German (DE) and English (EN) Factory setting: DE To activate the language selection the RAS+DL must be initialised by scrolling forward into the dis- play level. Time interval for continuous display TIME N Entry 0 = no automatic switching between displays Factory settings: 0 „0“...
Confirmation of the desired address via a long key press. Among those controllers that have no bidirectional data link (those for which the RAS+DL can only be used as a remote display, e.g. HZR65), this menu option is still displayed but has no effect and...
Index specification To process sensor values on the controller, specification and selection of the sensor address (1-8) and the index (1-11) is necessary. Indices can be selected for the following values: Index Value Room temperature with offset values for +/- adjustment the dip switch (to evaluate „RAS“ on controllers UVR1611 and UVR63-H (min.
ESR21, ESR31, UVR61-3, UVR63 and UVR63-H Adjustment of the measurements takes place in the menu EXT DL (external sensors) Example: The external sensor 1 has address 1, the measured room temperature is imported without offset values (index 2). In the controllers ESR31, UVR61-3, UVR63 and UVR63-H (version 5.0 up to 7.1), only the measured room temperature can be evaluated without offset values (index 2);...
Among those controllers that have no bidirectional data link (e.g. HZR65), i.e. those for which the RAS+DL can only be used as a remote display, this menu option is still displayed but has no effect and can therefore be disregarded.
Password allocation PASSW The purpose of this password is to block access to the CONFIG and VALUES menus. For access, enter the password set here. If 0000 is entered, no password is required. While the password is shown, long clicks can be used to go through the individual character places (active place flash- es) and a short click increases a place by 1.
Menu VALUES This is where the display is selected: • Sensor values SENSOR • Output statuses OUTPUT • Speed stages SPEED (only UVR16x2, RSM610, CAN-I/O45 and UVR 1611) • Heat quantity counter POWER (only for controllers with a heat quantity counter) •...
Menu output statuses OUTPUT Access the menu via a long key press. Selection via a long key press on the relevant output. The selection is indicated by a star sym- bol. Depending on the controller type, up to 14 out- put statuses can be displayed.
Menu speed stages SPEED (only UVR1611) Access the menu via a long key press. Selection via a long key press on the relevant output. The selection is indicated by a star. The speed of this output is displayed after all the other displays have been displayed.
Menu heat quantity counter POWER This menu option is only displayed for controllers with a heat quantity counter. Access the menu via a long key press. Selection via a long key press of the value of the respective heat quantity counter. The selection is indicated by a star.
Menu external sensors NETW (ESR21 > V5.0, ESR31, UVR61-3 > V8.3, UVR63 > V 1.5) This selection is only possible for the controllers listed above, as only these controllers can display external sensors via the data link. Access the menu via a long key press. Selection via a long key press at the relevant ex- ternal sensor.
Menu analogue CAN network inputs ANALNW (only UVR1611) This selection is only possible for the controller UVR1611. For output 14, the query NETW.IP.=>DL.: must be set to „yes“. Access the menu via a long key press. Selection via a long key press t the relevant an- alogue network input.
Menu digital CAN network inputs DIGINW (only UVR1611) This selection is only possible for the controller UVR1611. For output 14, the query NET- ZW.IP.=>DL.: must be set to „yes“. Access the menu via a long key press. Selection via a long key press at the relevant digital network input.
Menu symbol allocation SYMB This menu allows for allocation of a symbol (or several symbols) to display values. However, each symbol can only be allocated once. The following symbols can be allocated: Example: The symbol "Burner" is to be allocated to the output O5: Access the menu via a long key press.
Page 23
A long key press confirms the allocation of the "Burner" symbol to output O5. Flashing of the symbol stops. Scroll forward to the next symbol to be allocated or ..exit the menu by scrolling forward to "EXIT" If the symbol is allocated to an Output or a Digital CAN network input (UVR1611), then it is shown in each display view for as long as the output or the digital network input is set to "ON".
Deleting or changing a symbol allocation Example: Deleting or changing the "Burner" symbol allocation to output O5: Access the menu via a long key press. By scrolling forwards with short key presses, the desired "burner" symbol appears in the display. A long key press causes the allocation to be cleared.
A DL output is programmed on the controller; the address of the output must be the DL address of the RAS+DL (see "Addresses in the DL bus network DL ADR"). The index is shown on the display. In this example, the RAS+DL is given a dimensionless value of 7.0 using a DL output with index 1.
Reset to factory settings To reset the sensor RAS+DL to its factory settings, the key must be pressed during insertion of the data link into the sensor: The "RESET" display appears briefly Then the menu language is selected (DE = Ger-...
Operation Room sensor with UVR16x2, RSM610, CAN-I/O45, UVR1611 (> A3.00 and serial number >13285) or with UVR63-H (> V7.2) Pressing the Key causes the next value to be displayed. The basic display values are displayed in the following sequence. Then the pre-programmed values become visible. If there are outputs that are combined with a symbol, then the symbol is also displayed.
If the installation location of the room sensor is unsuitable as a reference room, the room sensor RAS+DL can also be used merely as a remote control, by using Index 5 as the measured value. Using this method, a fixed value of 20°C with offset values of the +/- setting and the slider switch are for- warded to the controller.
Electrical connections The sensor is connected to both DL connections. The polarity of DL and GND on the controller is re- versible. Alternatively, the 12 V connection can be used for the power supply to relieve the load on the DL bus. Otherwise, the sensor is supplied with power via the DL bus. Any cable with a cross section of 0.75 mm²...
Page 32
Note: The following warranty conditions do not in any way limit the legal right to warranty, but rather expand your rights as a consumer. 1. The company Technische Alternative RT GmbH provides a one-year warranty from the date of purchase for all the devices and parts which it sells. Defects must be reported immediately upon detection and within the guarantee period.