Gentherm 5220 Operating Manual page 16

Thermoelectric generator
Hide thumbs Also See for 5220:
Table of Contents

Advertisement

Power output
Power Ratings
20º C, 750 m above sea level
Electrical
Adjustment
Reverse Current Protection
Output
Fuel
Natural Gas
Propane
Maximum Supply Pressure
Minimum Supply Pressure
Fuel Connection
Environmental
Ambient Operating Temperature
Continuously Running TEG
Operating Conditions
Materials of Construction
Cabinet
Cooling Type
Fuel System
Note: Specifications shown are for standard configurations. Gentherm Global Power
Technologies (GPT) Applications Engineering Department is available to design
installations meeting different specifications including custom voltages, fuel sup-
ply systems and non-standard operating temperatures.
Gentherm Global Power Technologies
5220
220 Watts @ 12 Volts
178 Watts @ 24 Volts
12 V
24 V
Yes
Terminal block which accepts up to 8 AWG
wire. Opening for 3/4" conduit in the base of
the cabinet.
19.7 m
/day (698 ft
3
SCF (37.7 MJ/Sm
28.0 L/day (7.4 gal/day)
345 kPa (50 psig)
165 kPa (24 psig)
1/4" FNPT connection
Max. 45º C (115º F)
Min. -40º C (-40 ºF)
Unsheltered Operation
304 Stainless Steel
Natural Convection
Brass, Aluminum & Stainless Steel
28142 Rev. 14
12–18 Volts
24–30 Volts
/day) of Std. 1000 BTU/
3
) gas
3
3-2

Advertisement

Table of Contents
loading

Table of Contents