Summary of Contents for jbc JTSE-1UA

  • Page 1 INSTRUCTION MANUAL Hot Air Control Unit...
  • Page 2: Packing List

    This manual corresponds to the following references: JTSE-1UA (100V / 120V) JTSE-2UA (230V) Packing List The following items are included: JTU Control Unit ........1 unit Power cable ..........1 unit Ref. 0023715 (100V / 120V) 0023714 (230V) Manual ............1 unit Ref. 0027698...
  • Page 3: Features And Connections

    para manuales - color gris 200 mm Features and Connections 130 mm 130 mm Control Unit 100 mm USB-A Connector Heating Element 80 mm Thermocouple Type K 60 mm Activates the Suction Pump Hot Air Button 50 mm (On / Off) 40 mm A2330 Suction Tube for...
  • Page 4: Menu Options

    JT / TE Work Screen JT/TE offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105 Status Bar 19:29 Time to Stop 4m 38s Instant Power Supplied to Hot Air Temp. Air Flow Selec. Heater ºC Current Selected...
  • Page 5: Advanced Functionalities

    para manuales - color gris 200 mm 400ºC Selected Protection ºC Power Temp. 120ºC Selected Advanced Functionalities 130 mm 130 mm To work with profiles it is essential to use RWB / RWS / RWT rework arms. The Rework Arms supports the Hot Air Heater maintaining the distance and position to the component.
  • Page 6: System Notifications

    Insert a USB flash drive into the USB-A connector to save your soldering process in csv format. Files Station Update Download the JBC Update File from www.jbctools.com/software.html Insert the USB flash drive with the file down- loadedto the station. Update...
  • Page 7: Adjustable Stand

    para manuales - color gris 200 mm Adjustable Stand 130 mm 130 mm Adjust the tool holder angle to suit your work position. 100 mm 80 mm 60 mm Operation Modes 1. From the Tool Settings Menu, select the mode to activate the tool depending on the task. 50 mm Tool button Pedal...
  • Page 8: Operation

    Operation 1. Placing 2. Heating 3. Extracting Position the extractor with the Heat the component. The component lifts off appropriate suction cup and automatically when the press the suction button. solder melts. Protectors & Extractors For small components For large components (fig.
  • Page 9 para manuales - color gris 200 mm Accessories (not included) 130 mm 130 mm Protectors No.* Ref. AxB (mm) AxB (in) No.* Ref. AxB (mm) AxB (in) 4,3 x 3 0.16 x 0.12 12 x 23 0.47 x 0.9 P3353 P1249 100 mm P3786...
  • Page 10 Using the Thermocouple Type K Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor. You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu. You can choose from two work modes: Regulation: the station regulates the air Protection: the station cuts the air supply off...
  • Page 11 para manuales - color gris 200 mm Nozzle Extractor 130 mm 130 mm Turn the tool off and handle with care. The heating element and the nozzle are still hot. 1. Removing Nozzle 2. Attaching Nozzle 100 mm 80 mm 60 mm Place the heating element with its nozzle in the Attach the nozzle and press the nozzle onto the...
  • Page 12: Replacing The Heating Element

    Replacing the Heating Element Note: Only perform this operation when the element is cold and the unit is disconnected from the mains. Loosen the screw (1) and pull the worn heating element out of the handle (2). Insert the new heating element, make sure its pushed all the way in (2) and tighten the screw (1). Heating Element for JTT JTH1: Ref.
  • Page 13: Maintenance

    Employer uniquement avec Employer uniquement avec un fusible de 250V un fusible de 250V Fuse holder - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service.
  • Page 14 Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. Be sure that it is properly grounded before use.
  • Page 15: Specifications

    130 mm Hot Air Control Unit 100 mm Ref.: JTSE-1UA 100V - 120V 50/60Hz. Input fuse: 8A. Rated current: 7A Ref.: JTSE-2UA 230V 50/60Hz. Input fuse: 4A. Rated current: 3A - Temperature selection: Room temp. 150 - 450 °C / 300 - 840 °F...
  • Page 16 In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.