Sequence Of Operation - SanRex SANARG 160P Operator's Manual

Dc inverter arc welder
Table of Contents

Advertisement

SECTION 6 – SEQUENCE OF OPERATION
6.0

SEQUENCE OF OPERATION

NOTE: Scroll Buttons are used to select the parameters to be set. The
LED's show which function is being adjusted on the weld sequence graph.
Refer to Symbols Table located in the front of the manual for Symbol
descriptions.
1. Pulse Function – Pressing this button enables the TIG current pulse functions.
2. Scroll Buttons – Used to scroll through the available welding functions to be set as shown on the on the
welding sequence graph. The LEDs in the graphical representation will illuminate indicating which
function has been selected and available for adjustment. Once the desired function has been selected, use
the Encoder Knob to adjust the function's value.
3. Digital LED Display – Welding amperage and parameter values are displayed in this window. Internal
error codes such as over temperature, low or high input voltage applied and others are signaled to the
operator by means of a warning sound and indicated on the Digital LED display.
4. Encoder Knob – Rotating this knob will adjust the value of the function selected. This knob allows the
operator to adjust the output amperage within the entire range of the power source as well as adjusting the
value of each function. Pushing the knob inward displays actual welding voltage.
Figure 6-1 – 160P Front Panel