Installing Built-In Models

Built-In models require installation into a countertop before
operation. Two types of built-in installation are available, flush
mount and trim ring. Use the following information and the
appropriate procedure to install a built-in unit.
Preparing the Installation Site
Both types of built-in installation require the same general
cabinet specifications. The unit is designed to allow easy
removal of the electronic components from the underside of the
unit without having to remove the installed ceramic glass top.
IMPORTANT! Make sure that the installation location allows
access to the underside of the unit for maintenance and
cleaning after it has been placed into the countertop. Other
specifications include:
• Make sure a grounded electrical receptacle of the correct
voltage, size, and plug configuration is within reach of the
unit's 71" (1800 mm) power cord inside the cabinet. See
the SPECIFICATIONS section for details.
• Make sure a vertical surface for control panel installation is
available in the cabinet within reach of the combined 55"
(1397 mm) control cables that connect the induction range
to the control panel.
• Make sure a minimum clearance of 1-1/2" (38 mm) will
be available between the sides of the unit and any interior
surface.
• Make sure a minimum clearance of 2" (51 mm) will be
available between the front and back of the unit and any
interior surface.
• Make sure a minimum clearance of 4-1/2" (114 mm) will be
available between the bottom of the unit and any interior
surface.
2"
2"
Rear Cooling
Fans (inside)
Ventilation
Opening
(Min. 40 in²)
NOTE: Walls of cabinets removed
IRNGCDM-0522
Front of Unit
Front Cooling
Fan (inside)
Ventilation
Opening
(Min. 40 in²)
for clarity.
Side View
Installation Setbacks for Built-In Models
Ventilation Requirements
Proper ventilation of the cabinet below a built-in unit is required
to prevent over-heating the electronics in the unit. Proper
ventilation provides cool, intake air to the front of the unit and
an escape for the hot, exhaust air from the back of the unit.
• For standard installations, a ventilation opening with a
minimum size of 4" x 10"/40 square inches (10 x 25 cm/
258 square cm) is required behind the air exhaust openings
on the back of the unit, starting no more than 2" (51 mm) down
from the top of the unit. An additional 4" x 10"/40 square inch
(10 x 25 cm/258 square cm) ventilation opening is required
in the front of the cabinet to provide cool intake air. Louvered
or grill-style panels should be installed in the openings.
• For installations where the cabinet is against a wall or no
rear ventilation is possible, keep the front control-side of
the cabinet open. If the front cannot be left open, install two
ventilation openings in the front panel of the cabinet, one at
the bottom of the cabinet and one near the control panel at the
top of the cabinet. Each opening must be a minimum size of
4" x 10"/40 square inches (10 x 25 cm/258 square cm). DO
NOT install a shelf, partition, or any other equipment
inside the cabinet underneath the unit—the space
must remain wide open for air circulation.
NOTE: Make sure the interior temperature of the cabinet
does not rise above 122°F (50°C) while the induction
range is operating. If the temperature rises too high,
additional ventilation openings or forced air cooling will
be required.
2"
Min.
1-1/2"
Control
Panel
Opening in front
of cabinet for
installations
with no rear
ventilation
options.
9
INSTALLATION
Sides of Unit
Min.
1-1/2"
Front view of ventilation
opening in cabinet.
Front View