Owner's Manual Original Instructions Split Air Conditioner CONTENTS Safety precautions ..................Parts name ....................Operation and introduction of remote contr oller ..........Clean and maintenance ................Checked items before maintenance ............. Installation notice ..................Installation of indoor unit ................Installation of outdoor unit ................
Page 2
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
Safety precautions WARNING Installation Installation or maintenance The grounding resistance must be performed by qua- should comply with nation- lified professionals. al electric safety regula- The appliance shall be in- tions. stalled in accordance with Air Conditioner should be national wiring regulations. properly grounded.
Page 4
Safety precautions CAUTION Installation Instructions for installation For the air conditioner with- and use of this product are out plug, a circuit breaker provided by the manufac- must be installed in the turer. line. Select a location which is The yellow-green wire in out of reach for children air conditioner is ground- and far away from animals...
Page 5
Safety precautions WARNING Operation and Maintenance tioner to multi-purpose soc- This appliance can be used ket. Otherwise, it may cau- by children aged from 8 se fire hazard. years and above and per- Do disconnect power supp- sons with reduced physi- ly when cleaning air condi- cal, sensory or mental ca- tioner.
Page 6
Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
Operation and introduction of remote controller Introduction for icons on display Buttons on remote controller screen I feel Set fan speed Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep mode heating function Health mode On/Off Mode Scavenging function...
Page 9
Introduction for buttons on remote controller This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to Notice avoid mould. ● This is a general use remote controller. It could be ● Having set X-FAN function on: After turning off the unit used for the air conditioner with multifunction.
Page 10
P ss his " P ss his ss his P ss his " Function introduction for combination buttons " P ss his P ss " " " " is is ss g high i g i "MODE" " " wi hi swi h i OFF, ss "MODE"...
Page 11
Replacement of batteries in remote controller Notice...
Clean and maintenance WARNING The filter should be cleaned every three months . If there is much dust in the operation environme- WARNING nt, clean frequency can be increased. Turn off the air conditioner and disconnect the After removing the filter, do not touch fins to power before cleaning the air conditioner to av- avoid injury.
Checked items before maintenance Phenomenon Solution Check items Whether there’s od- General phenomenon analysis Eliminate the odour Odours are our source, such as source. Clean the Please check below ite ms before asking for furniture and cigare- emitted filter. maintenance. If the malfunction still can’t be tte, etc.
Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
Page 15
Selection of installation location Requirements for electric connection Basic requirement 3.Make sure the power supply matches with the requirement of air conditioner. Unstable power Installing the unit in the following places may cau- supply or incorrect wiring or malfunction. Pl- se malfunction.
Installation of indoor unit Notice Indoor outdoor Pay attention to dust prevention Step 1: sures when opening the hole. Choose installation location 5-10 Recommend the installation location to the client and then confirm it with the client. Step 2: Step 4: Install wall-mounting frame Outlet pipe 1.Hang the wall-mounting frame on the wall;...
Page 17
drain hose Hex nut diameter Tightening torque (N m) 15~20 30~40 45~55 insulating pipe Notice 70~75 Add insulating pipe in the indoor drain hose in order Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it Step 7: with tape Connect wire of indoor unit...
Page 18
drain hose connection pipe Remove the wire clip; connect the power conn- band ection wire to the wiring terminal according to the color; tighten the screw and then fix the po- wer connection wire with wire clip. indoor power cord Bind them evenly.
Installation of outdoor unit Step 1: Fix the support of outdoor unit (select it according to the actual inst- drain vent allation situation) chassis 1. Select installation location according to outdoor drain joint Drain hose the house structure. Fix the support of outdoor unit on the sele- cted location with expansion screws.
Page 20
Step 6: Tighten the union nut with torque wrench Neaten the pipes by referring to the sheet below. The pipes should be placed along the wall, bent Tightening torque(N m) Hex nut diameter reasonably and hidden possibly. Min. semidiam- 1/4'' 15~20 eter of bending the pipe is 10cm.
Test and operation Check after installation ● Check according to the following requirement Use vacuum pump after finishing installation. Remove the valve caps on the liquid valve and Items to be checked Possible malfunction gas valve and the nut of refrigerant charging vent. 2.
Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe is 3m. Max. length of connection pipe is shown as below. Max. length of connection pipe Max.
Page 23
B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the ● burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal Working temperature range Indoor side Outdoor side C: Put on suitable insulating pipe DB/WB(°C)