Summary of Contents for MegaLife ML-PC10AO-K5NNA1A
Page 1
Owner's Manual Original Instructions Portable air conditioner Model: ML-PC10AO-K5NNA1A ML-PH12AO-K5NNA1A ML-PC12AO-K5NNA1A Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
Content Operation Notices Safety precautions ..................... Operation Environment ..................Parts Name ......................Operation Guide Operation Introduction for Control Panel ............... Using the remote controller ................... Buttons on Remote Controller ................Introduction for Icons on Display Screen .............. . Introduction for Buttons on Remote Controller ............Function Introduction for Combination Buttons .............
Page 3
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
Page 4
The refrigerant Should repair be necessary,contact your nearest Before install the Appliance filled authorized Service Centre. Any repairs carried out appliance, read with flammable by unqualified personnel may be dangerous. the installation gas R290. Compliance with national gas regulations shall manual first.
Safety precautions WARNING This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Safety precautions WARNING Do not put or hang dripping objects above the air conditioner. Do not repair or disassemble the air conditioner by yourself. Prohibit inserting any objects into the air conditioner. Do not through sundries into the air duct. If there are sundries get into the air duct, please contact the professionals to deal with it.
Parts name Controller panel Guide louver Filter Air inlet Middle drainage port Bottom drainage port OPER On/Off Mode Swing Sleep Timer Health WiFi Remote controller NOTICE Some installation accessories can't be discarded. ●...
Buttons on remote controller Oper ation of control panel setting is finished, the unit will display temper- ature if there’s no operation for 5s. If timer fun- OPER ction is started up, the upper indicator will keep the display status. Others, it won’t be displayed. Under timer mode, press timer button again to cancel timer mode.
● Under timer setting status, after each pressing of Introduction for buttons on “+” or “-” button, time will increase or decrease 0.5h . remote controller Hold “+” or “-” button, 2s later, time displayed on NOTE dual-8 nixie tube will change quickly. Loosen the bu- ●...
Introduction for buttons on NOTICE remote controller ● The distance between signal sender and receiving button for the third time to quit health and scaven- window should be no more than 8m, and there should ging functions simultaneously. Press the button for be no obstacles between them.
NOTICE Clean and maintenance ● The filter should be cleaned about once every three months.If there’s much dust in the operation envir- WARNING onment, you can increase clean frequency. ● ● Do not dry the filter with fire or hair drier.Otherwise, Before cleaning the air conditioner, please turn it may be deformed or catch fire.
Malfunction analysis Phenomenon Solution Check items Whether air outlet or Eliminate the obstacles. air inlet is blocked? Please check below items before asking for main- tenance. If the malfunction still can’t be eliminated, Under heating mode, The unit will stop blo- please contact local dealer or qualified professionals.
The place with high-frequency devices (such as max |Zsys| unit:ohm models welding machine, medical equipment). ML-PC10AO-K5NNA1A 3. The place near coast area. ML-PH12AO-K5NNA1A 0.13 4. The place with oil or fumes in the air. ML-PC12AO-K5NNA1A 5. The place with sulfureted gas.
Preparation before Installation Optional 2 NOTE ● Check if the accessories are available before insta- llation. Accessory list Rear clip Optional 3 Joint A Heat discharge pipe Joint D Joint H Screws Drain connector Power cord hooks OPER On/Off Mode Swing Sleep Timer...
Install Power cord Hooks Remove the rubber plug of the bottom drainage port to drain water. After draining, insert the rubber plug. ● Assemble the power cord hooks at the back of Press ON/OFF button to restart. the unit with screws (the direction of power cord hooks is as shown in following fig).
Page 17
Drain Water 2. Screw the drain connector to (included in the package) the spout by turning clockwise. Insert the drainage hose into drain connector. ATTENTION: When using continuous drainage option from the middle hole, place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward.
Installation in sash window (Optional 1) Operation instruction for Mounting Accessories of Window kit. The dimension of the window kit as below. Fixed base (Unit:mm) Extension panel Mounting Fixed base plate Fixed clip Adjustment Adjustment panel panel Window panel Fixed base Fixed base 1210-1650 Window...
Page 19
Insert the Exhaust cover to the Window Panel. Insert the first groove For windows with inner width or height over 1210mm up to 1650mm. Use two fixed bases, Adjustment Panel ,Extension panel, Mounting Assemble the window kit as below. plate and fixed clip. For windows with inner width or height of Push one fixed base to the end of Window 770mm, push two fixed bases to the end of...
Double-hung sash window (Optional 1) Close the window sash securely against the Window panel. 1. Cut the Foam seal (adhesive type) to the proper length and attach it to the window stool and to the bottom of sash. Foam seal (adhesive type) 2.
Sliding sash window (Optional 1) Cut the Foam seal B (adhesive type) to the proper Close the window sash securely against the length and attach it to the window frame and to window panel. the side of sash. Foam seal B (adhesive type) Install the window panel into the window frame.
Installation and disassembly of heat discharge pipe (Optional 1&2) Note of Installing heat discharge pipe Install heat discharge pipe In order to improve cooling efficiency,the heat discharge pipe should be as short as possible Rotate joint A and Rear clip clockwise into and flat without curve to ensure smooth heat the two ends of heat discharge pipe.
Installation of Heat Discharge Pipe Optional 3-2: Installation in immovable window Optional 3-1: Installation Rotate joint A into the ends of heat discharge in the window pipe. Fold the rear joint inwards unit these two clasps have tightly connected the rear joint together. Heat discharge pipe Joint A If the window is immovable, cut a hole to install...
Disassembly of Heat Discharge Pipe Optional 3-1: Disassembly for installation in window Optional 1 & 2: Remove joint A: Disassemble for installation in dou- Press the clasp and lift joint A upwards to remove it. ble window Groove Remove joint A: joint A Press the clasp and lift joint A upwards to remove it.
/OFF button on remote controller to start the unit. Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit ML-PC10AO-K5NNA1A 、 ML-PC12AO-K5NNA1A operates normally. The Electric schematic diagram are subject to change If ambient temperature is below 16°C(61°F) , the...
Specialist’s Manual Aptitude requirement for maintenance man(repairs should be done only be specialists). Safety preparation work...
Page 27
Specialist’s Manual are constructed of materials which are inherently mitted for the equipment in use. Intrinsically safe components are the only types resistant to being corroded or are suitably protec- that can be worked on while live in the presence of ted against being so corroded.
Page 28
Specialist’s Manual wed since flammability is a consideration. The foll- the technician is completely familiar with the equipm- owing procedure shall be adhered to: ent and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the remove refrigerant;...
Page 29
Specialist’s Manual that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
Need help?
Do you have a question about the ML-PC10AO-K5NNA1A and is the answer not in the manual?
Questions and answers