WARNING
Properly installed and maintained, the PanBlast
AirScan Mobile CO Monitor will measure the level of
carbon monoxide and many toxic hydrocarbons in the
compressed air sample. The instrument does NOT
remove or convert carbon monoxide.
VISUAL INDICATORS, CONTROLS AND AUDIO
INFORMATION
Using Figure 3 as a reference, the following lists the
function of the indicators and controls used in operating
and calibrating the PanBlast
The audio alarms related to these controls are noted:
1)
Horn
2)
External alarm/status light. This indicator will
be GREEN, RED or YELLOW.
GREEN: No alarm condition.
RED: Carbon monoxide or hydrocarbons have
exceeded the pre-set alarm limits.
YELLOW:
Indicates
conditions: -
Warm-up period two minutes (No Audio).
RUN/CAL switch in CAL position (10 second
beep).
LOW-pressure condition (10 second beep).
HIGH-pressure condition (10 second beep).
3)
The
air
quality
instrument operator knowledge of the alarm
condition of the toxic gas sensor. When the
sample air contamination exceeds the pre-set
alarm limit the calibration status indicator will
turn red. When the contamination is less than
the pre-set alarm limit the indicator will be
green.
4)
The calibration adjustment control screw is
used only during the calibration procedure
covered later in this manual.
5)
The RUN/Calibration selection valve control
allows the instrument technician to select the
source of the sample gas to the instrument.
In the Run mode the sample is from the
breathing air system and in the calibration
mode the sample comes from the calibration
gas port.
6)
The
flow
meter
illuminated indication of flow through the
instrument. This flow should be about 0.5 SCFH,
which is mid-range on the indicator.
7)
The calibration gas input port provides the
capability to introduce calibration gases to the
instrument sensor when the calibration/Run
valve is in the calibration mode.
8)
Faceplate/door screw
9)
Internal sample flow regulator
10)
Sample input port
11)
Line cord
12)
Accessory plug
AirScan Mobile CO Monitor.
TM
one
of
four
possible
indicator
provides
the
indicator
provides
an
TM
5.0
INITIAL SET-UP
5.1
Confirm that the installation of the PanBlast
AirScan Mobile CO Monitor is consistent with
the requirements illustrated in the installation
section of this manual.
5.2
Confirm that users have read this manual and
are familiar with the operation of the PanBlast
AirScan Mobile CO Monitor.
5.3
The following startup procedure is based on the
PanBlast
new factory calibrated unit or a unit being
returned to service with proper calibration.
5.4
The PanBlast
should be powered up electrically first and then
the sample flow initiated.
5.5
Using the Sample regulator #9, Figure 3
accessed by loosening the faceplate screw #8,
Figure 3. Adjust (top of regulator) the flow to
the
instrument
illuminates a midrange of the GREEN indicator
lights. The RUN/CAL switch must be in the RUN
position.
Observe the visual indicators for a minute or
slightly more.
Air Quality Indicator – RED briefly – then
GREEN.
Alarm Status Indicator - YELLOW warm-up
period - then GREEN.
5.6
With the visual indicators all GREEN, move the
RUN/CAL switch to the CAL position. This will
stop the sample flow to the sensor and the
ALARM STATUS INDICATOR will immediately
turn YELLOW.
The alarm horn will initiate an intermittent
alarm (10 Seconds)
5.7
Move the RUN/CAL switch to the RUN position.
Warm-up will be initiated and the audio will
terminate. In two minutes the instrument will
return to normal operation and all lights will
become GREEN if the sample air is clean.
Prior to putting a PanBlast
Monitor into service after successful startup the
following RESPONSE CHECK procedure should
be
completed
calibration.
- 3 -
Figure 3
AirScan Mobile CO Monitor being a
TM
AirScan Mobile CO Monitor
TM
until
the
flow
AirScan Mobile CO
TM
to
confirm
an
TM
TM
indicator
operational

Advertisement

Table of Contents
loading

Related Products for Panblast ZVP-PC-0080-00

Table of Contents