Download Print this page

Chapter 7. Service Precaution - Sharp ER-A450 Service Manual

Electronic cash register
Hide thumbs Also See for ER-A450:

Advertisement

CHAPTER 7. SERVICE PRECAUTION

1. Error code table
When the following error codes are displayed, press the
Error
code
E01
Registration error
E02
Misoperation error
E03
Undefined code is entered.
E04
Paper empty
E05
Secret code error
E07
Memory is full.
E11
Compulsory depression of the
E12
Compulsory tendering
E22
Overlapped cashier error
E23
Cashier resetting over error
E31
Compulsory non-add code entry
E32
No entry of your cashier code
E33
The current cashier code should not be changed.
E34
Overflow limitation error
E35
The open price entry is inhibited.
E36
The preset price entry is inhibited.
E37
The direct finalization is inhibited.
E58
Undefined clerk code is entered
E67
Registration buffer is full.
E76
The drawer is still opened.
E86
Communication error
E87
Data format error
E88
Time-out error
2. Conditions for soldering circuit parts
To solder the following parts manually, follow the conditions described below.
PARTS NAME
Front LED
VHPHDSP5621-1
(HDSP5621)
Pop-up LED
VHPHDSPF501-1
(HDSP-F501#S02)
3. Caution to be taken when removing the TOP CABINET
After removing the ER-A450's TOP CABINET from the BOTTOM CABINET, put the TOP CABINET on the positions given below to prevent the cable
that connects the MAIN PWB and POWER SUPPLY PWB from disconnecting.
1) Put the TOP CABINET on the left of the BOTTOM CABINET.
Put a sheet on the BOTTOM CABINET and put the TOP CABINET
upright on the sheet, as shown below.
[ Front view ]
Top cabinet
Sheet
j
key and take a proper action according to the table below.
Error status
s
key for direct finalization
PARTS CODE
Main PWB
Cable
Power supply PWB
Power transformer
Bottom cabinet
Drawer
Make a correct key entry.
Make a correct key entry.
Enter a correct code, or declare it by the programming.
Replace a journal paper roll with a new one.
Enter a correct secret code.
Expand the file within a capacity of memory.
s
Press the
key and continue the operation.
Make a tendering operation.
Enter a non-add code.
Make a cashier code entry.
Change a cashier after finalizing the transaction.
Make a registration within a limit of entry.
Make a preset price entry.
Make an open price entry.
Make a tendering operation.
Enter a correct clerk code.
Close the drawer.
SRV #996/#998
SRV #996/#998
SRV #996/#998
LOCATION
Front LED PWB: FND1-5
Pop-up LED PWB: FND1-10
2) Put the TOP CABINET behind the drawer
Put a base (proper height) behind the drawer and put the TOP
CABINET upright on the base, as shown below.
[ Right side view ]
Power supply PWB
Bottom cabinet
Drawer
7 – 1
Action
CONDITIONS FOR SOLDERING
315°C/2 sec.
315°C/2 sec.
Main PWB
Power transformer
Cable
Top
cabinet
Base

Hide quick links:

Advertisement

loading