CHAPTER 7. DATA BLOCK FORMAT

1. Basic format
1) ID-ENQ :
EOT is set as dummy cahracters. (3 bytes)
2) ACK :
1 byte 06h
3) NAK :
1 byte 15h
4) EOT :
1 byte 04h
5) ENQ :
1 byte 05h
6) TEXT :
Data ASCII (max. 250 bytes)
Block consecutive No.
Start code
Start code : This code may not be provided.
Null is impermissible.
End code : This code may not be provided.
Null or any same code as the start code is
not permissible.
When master reset is performed, the default is assumed:
Start code = 02h
End code = 0Dh
Block consecutive No. : This number starts with 30h and cycles
like this: 30h, 31h — 39h, 30h, 31h (Ring
counter system)
Check sum
: 2 bytes hex number
Low-order 8-bit data of the complement of
2 for the sum of text data.
RAM data:
: Even number of data that is obtained by
dividing one byte of RAM data into high-
order 4 bits and low-order 4 bits and con-
verting them to ASCII codes shown in the
code conversion table.
Code conversion table .
Print code (high-order or low-order 4 bits)
Bit image
Hexadecimal
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
10bytes
ENQ code (05h)
Terminal No. 000001-999999 (6 bytes)
End code
Check sum
Line image
ASCII
0
30h
1
31h
2
32h
3
33h
4
34h
5
35h
6
36h
7
37h
8
38h
9
39h
A
41h
B
42h
C
43h
D
44h
E
45h
F
46h
Example
Memory image
Line image

CHAPTER 8. ONLINE application

1. ONLINE preset
1) SRV programming: NONE
2) PGM programming
Job#
PGM-MODE programming for online operation
2690
The assignment of RS232 channel by each devices.
6110
Programming of the terminal number
6111
Programming of the modem control
6112
Programming of the transmission data rate (Bau rate)
6113
Programming of the start and end code.
6115
Programming of time out value
6110
Online Preset reading
[JOB#2690] MRS = 0000
The assignment of RS232 channel by each devices.
2690
X
X: 1
A:
On-line
No
Yes (Channel No. = 8)
[JOB#6110] MRS = 000001
Programming of the terminal number
6110
NK: Terminal No. = 0 to 999999
– 14 –
1
2
3
02
5A
F0
1
2
30h
32h
35h
41h
46h
Transmission sequence
0
X
ST
ABCD
X
2690-A
0
8
0
x
TL
NK
3
30h
TL

Hide quick links: