LG LRSC26925SW, LSRC26923SW, LRSC26925TT, LSRC26923TT User Manual page 11

Lg refrigerator user's manual
Hide thumbs Also See for LRSC26925SW, LSRC26923SW, LRSC26925TT, LSRC26923TT:
Table of Contents

Advertisement

Installation
Connect
1. Unplug refrigerator or disconnect power.
the Tubing to
2. Turn OFF main water supply. Turn on the nearest faucet to relieve the pressure
Water Line
3. Find a 1/2-inch to 1-1/4-inch vertical COLD water pipe near the refrigerator.
4. To determine the length of copper tubing you will need, measure from the
5. Using a drill, drill a 1/4-inch hole in the cold water pipe you have selected.
6. Fasten shut-off valve to cold water pipe with pipe clamp. Be sure outlet end is
7. Slip compression sleeve and compression nut on copper tubing as shown.
8. Place the free end of the tubing into a container or sink, and turn ON main
111
on the line. It may help to open an outside faucet to allow the water to drain from
the line in the house.
NOTE
Horizontal pipe will work, but the following precaution must be taken: Drill on the top of
the pipe, not the bottom. This will help keep water away from the drill. This also keeps
normal sediment from collecting in the valve.
connection on the lower left rear of the refrigerator to the water pipe. Add 7
feet (2.1m) to allow for moving refrigerator for cleaning. Use 1/4-inch O.D.
(outside diameter) copper tubing. Be sure both ends of copper tubing are cut
square.
solidly in the 1/4-inch drilled hole in the water pipe and that the washer is
under the pipe clamp. Tighten packing nut. Tighten the pipe clamp screws
carefully and evenly so washer makes a watertight seal. Do not overtighten or
you may crush the copper tubing, especially if soft (coiled) copper tubing is
used. Now you are ready to connect the copper tubing.
Insert end of tubing into outlet end squarely as far as it will go. Screw
compression nut onto outlet end with adjustable wrench. Do not over tighten.
water supply and flush out tubing until water is clear. Turn OFF shutoff valve
on the water pipe. Coil the copper tubing as shown below.