Waterfall control handle Air control handle Main diverter handle Aromatherapy control handle 11-12 Operating your Lorne Luxury Spa Setting the time Setting the cycle cleaning Setting the cycle heating Turning on the heater manually – maintaining heat Turning on the hot water massage pump...
IMPORTANT SAFETY INSTRUCTIONS Your physiological response to hot water is very subjective and depends on your age, health and medical history. If you don’t know your tolerance to hot water or experience dizziness, headaches or nausea you should exit the spa immediately and cool down. WARNINGS Children in and around the spa should be supervised at all times by a responsible adult.
HYPERTHERMIA Since your spa can be set to reach temperatures of 40°C (104°F) users should be aware that extended submersion in water that exceeds normal body temperature can lead to hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 37°C (98.6°F).
You will need a suitable electrical supply to run the spa. The Lorne Luxury Spa requires a hardwired 32Amp Residual Current Device Protected Dedicated Power Connection. Your Licenced Electrical Contractor can hardwire the spa straight to the meter box in your house or they can install a hardwired 32Amp residual current device protected dedicated isolation switch.
IMPORTANT USAGE WARNINGS – NON WARRANTY FAULTS Spas are extremely delicate products and require regular maintenance. Below we will list a number of common causes of problems which are not covered under this warranty. Should we ever need to visit you to repair your spa you will be charged the full cost of a repair if we found that the cause was the result of poor maintenance or customer negligence.
to be careful to not just apply the amounts of chemical that they tell you to apply. The reason for this is that they might set the parameters differently to what your spa requires. Water chemistry test history showing results for Free Chlorine, Total Chlorine, pH, Alkalinity, Calcium Hardness &...
To help avoid this problem ensure you fill up the spa through the filter box. You can tell if you have an air lock by turning on the pumps, if no water appears to circulate through the system it is very likely that you have an air lock.
DRAINING THE SPA - USING THE DRAIN FITTING WARNING: Never drain or partially drain your spa of water in sunlight hours. Always drain your spa at night time & fully refill your spa with water the same night. An empty or partially empty spa of water during sunlight hours can cause deforming, melting, crazing, discolouration, blisters or holes in the spa’s fiberglass, acrylic and fittings, this can happen within minutes of the spa being emptied or partially empty.
Page 10
MY SPA IS TOO HOT IN SUMMER, THE TEMPERATURE OF THE WATER IS HIGHER THAN I HAVE During summer there may be times when the spas water exceeds the set temperature. This is not a fault in the spa it is simply the ambient air temperature causing this. To combat this problem, you can use ice to cool down the water.
OPERATING YOUR LORNE LUXURY SPA • Your spa has two modes of operation, Standby and Active modes. • To switch between Standby and Active modes press • The spa will display ‘---’ to indicate that the spa is in Standby mode.
Page 12
OPERATING YOUR LORNE LUXURY SPA BUTTON FUNCTION MODE Turns on Water Jets 1 Active Mode Only Active Mode Only Turns on Water Jets 2 No Function Active Mode Only Air Blower Active Mode Only Turns on Heater for Manual Active Mode Only Heating (Jets 1 &...
SETTING THE TIME When turning on the spa for the first time you will need to set the clock time. To set the clock time the spa must be in Standby mode. Please ensure the spa is in Standby Mode (---). The three horizontal dashes must be displayed. Press the button to enter the time setting mode.
SETTING THE CYCLE HEATING Use the preheating function at the same time you run your cleaning cycle. Ensure the spa is in Standby Mode (---) Press Now enter the time of day you want the spa to begin preheating using a 24- hour clock. (Use the same time set for the cleaning cycle).
TURNING ON THE HEATER MANUALLY- MAINTAINING HEAT Ensure the spa is in Active Mode. Press the button to adjust the temperature to the desired temperature. Press this button to turn on the heater manually. You will see the word heat flashing on the touchpad, once the heat word goes solid and stops flashing the spa is heating.
Ensure the spa is in Active Mode. Press this button once to turn on the lights, the lights will now alternate between a number of colours. To hold a particular colour press this button second time. To turn the lights off press the button a third time FROST PREVENTION SYSTEM If the temperature of the spas water drops below 5°C the spa will switch on the heater until the spa reaches the temperature of 8°C.
Page 17
Symptoms Possible Cause(s) Possible Resolutions No Power MCB Switch off Check MCB Inadequate wiring of power to spa Consult electrician Fuse blown in control box Replace fuse RCD Tripped Reset RCD Connected Improperly Consult electrician No Circulation Impeller clogged Access and clean Water level too low Top up water RCD Repeatedly Tripping...
Need help?
Do you have a question about the Lorne Luxury and is the answer not in the manual?
Questions and answers