Page 2
Turning jets on & off Waterfall control handle Air control handle Main diverter handle Aromatherapy control handle 10-11 Operating your Trinity Deluxe Spa Setting the time Setting the cycle cleaning Setting the cycle heating Turning on the heater manually – maintaining heat...
IMPORTANT SAFETY INSTRUCTIONS Your physiological response to hot water is very subjective and depends on your age, health and medical history. If you don’t know your tolerance to hot water or experience dizziness, headaches or nausea you should exit the spa immediately and cool down. WARNINGS Children in and around the spa should be supervised at all times by a responsible adult.
HYPERTHERMIA Since your spa can be set to reach temperatures of 40°C (104°F) users should be aware that extended submersion in water that exceeds normal body temperature can lead to hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 37°C (98.6°F).
You will need a suitable electrical supply to run the spa. The Trinity Deluxe Spa requires a 10Amp Residual Current Device Protected Dedicated Power Connection. Your Licenced Electrical Contractor can hardwire the spa straight to the meter box in your house or they can install a 10Amp residual current device protected dedicated single power plug.
IMPORTANT USAGE WARNINGS – NON WARRANTY FAULTS Spas are extremely delicate products and require regular maintenance. Below we will list a number of common causes of problems which are not covered under this warranty. Should we ever need to visit you to repair your spa you will be charged the full cost of a repair if we found that the cause was the result of poor maintenance or customer negligence.
Page 7
just apply the amounts of chemical that they tell you to apply. The reason for this is that they might set the parameters differently to what your spa requires. Water chemistry test history showing results for Free Chlorine, Total Chlorine, pH, Alkalinity, Calcium Hardness & Cyanuric Acid, must be kept as a dated once-a-month digital reference as part of your warranty terms.
Place your hardcover on the spa and position it to fold in the direction of your preference. On each strap of the hardcover there is a black plastic lock. Press the two prongs on each lock together and gently pull downwards to remove the section of the lock which you will need to screw onto the spas cabinet. With the section of the lock you have in your hand place it behind the prongs which are attached to the hardcover strap lined up so that the bottom of each part is flush.
Page 9
To locate your drain fitting it will be found on the touchpad side of the spa in either the left or right hand corner of the black fibreglass base underneath the synthetic cabinet. When you want to operate the drain fitting turn the handle clockwise and at the same time pull the handle away from the spa to release from the locking keyway.
Page 10
OPERATING YOUR TRINITY DELUXE SPA • Your spa has two modes of operation, Standby and Active modes. • To switch between Standby and Active modes press • The spa will display ‘---’ to indicate that the spa is in Standby mode.
Page 11
Sets Temperature Active Mode Only No Function Active Mode Only Turns on LED Lights Active Mode Only...
Page 12
OPERATING YOUR TRINTY DELUXE SPA BUTTON FUNCTION MODE Turns on Water Jets 1 Active Mode Only No Function Active Mode Only No Function Active Mode Only Air Blower Active Mode Only Turns on Heater for Manual Active Mode Only Heating (Jets 1 must be off) Starts Cycle Cleaning Standby Mode Only...
SETTING THE TIME When turning on the spa for the first time you will need to set the clock time. To set the clock time the spa must be in Standby mode. Please ensure the spa is in Standby Mode (---). The three horizontal dashes must be displayed. Press the button to enter the time setting mode.
Page 14
SETTING THE CYCLE HEATING Use the preheating function at the same time you run your cleaning cycle. Ensure the spa is in Standby Mode (---) Press Now enter the time of day you want the spa to begin preheating using a 24- hour clock. (Use the same time set for the cleaning cycle).
Page 15
TURNING ON THE HEATER MANUALLY- MAINTAINING HEAT Ensure the spa is in Active Mode. Press the button to adjust the temperature to the desired temperature. Press this button to turn on the heater manually. You will see the word heat flashing on the touchpad, once the heat word goes solid and stops flashing the spa is heating.
Ensure the spa is in Active Mode. Press this button once to turn on the lights, the lights will now alternate between a number of colours. To hold a particular colour press this button second time. To turn the lights off press the button a third time FROST PREVENTION SYSTEM If the temperature of the spas water drops below 5°C the spa will switch on the heater until the spa reaches the temperature of 8°C.
Page 17
No Power MCB Switch off Check MCB Inadequate wiring of power to spa Consult electrician Fuse blown in control box Replace fuse RCD Tripped Reset RCD Connected Improperly Consult electrician No Circulation Impeller clogged Access and clean Water level too low Top up water RCD Repeatedly Tripping Power Supply...
Need help?
Do you have a question about the Trinity Deluxe Spa and is the answer not in the manual?
Questions and answers