NEW BRUNSWICK SCIENTIFIC CO28IR Manual To Operation

Water-jacketed co2 incubator with hepa filtration

Advertisement

Quick Links

CO28IR
Water-Jacketed
CO
Incubator
2
with HEPA filtration
M1271–0051
Revision A
January 20, 2004
NEW BRUNSWICK SCIENTIFIC CO., INC.
BOX 4005 • 44 TALMADGE ROAD • EDISON, NJ 08818-4005
Telephone: 1-732-287-1200 • 1-800-631-5417
Fax: 732-287-4222 • Telex: 4753012 NBSCO
Internet: http://www.nbsc.com • E-mail: bioinfo@nbsc.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CO28IR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NEW BRUNSWICK SCIENTIFIC CO28IR

  • Page 1 Incubator with HEPA filtration M1271–0051 Revision A January 20, 2004 NEW BRUNSWICK SCIENTIFIC CO., INC. BOX 4005 • 44 TALMADGE ROAD • EDISON, NJ 08818-4005 Telephone: 1-732-287-1200 • 1-800-631-5417 Fax: 732-287-4222 • Telex: 4753012 NBSCO Internet: http://www.nbsc.com • E-mail: bioinfo@nbsc.com...
  • Page 2 CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 3 Fax: 49 (0)7022 32486 E-mail: sales@nbsnv-sa.be E-mail: sales@nbsgmbh.de CHINA THE NETHERLANDS New Brunswick Scientific Co., Inc. New Brunswick Scientific BV Room 1501, Xiangjiang Building, No. 18 Kerkenbos 1101, 6546 BC Nijmegen Lane 1265, Zhongshan Road (W) P.O Box 6826, 6503 GH Nijmegen Shanghai 200051, P.R.
  • Page 4 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 5 Do not use this equipment in a hazardous atmosphere or with hazardous materials for which the equipment was not designed. New Brunswick Scientific Co., Inc. (NBS) is not responsible for any damage to this equipment that may result from the use of an accessory not manufactured by NBS.
  • Page 6 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 7 Reproduction, adaptation, or translation without prior written permission from New Brunswick Scientific is prohibited. Disclaimer Notice New Brunswick Scientific Co., Inc. reserves the right to change information in this document without notice. Updates to information in this document reflect our commitment to continuing product development and improvement.
  • Page 8 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 9 W A R R A N T Y Every Instrument manufactured by the New Brunswick Scientific Co., Inc. is warranted to be free from defects in material and workmanship. This apparatus, with the exception of glassware, lamps and electrodes (where supplied), is...
  • Page 10 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 11: Table Of Contents

    ................. 21 RAINING THE ATER ACKET FYRITE CO CHECKING....................23 MAINTENANCE......................25 ........................25 LEANING ......................25 AINTENANCE ..............26 EPLACING THE NTERNAL ILTER HEPA F .................. 26 EPLACING THE ILTER ........................27 TORAGE TROUBLESHOOTING ....................29 New Brunswick Scientific User’s Manual...
  • Page 12 These units are not intended for hazardous or domestic use. CO28IR CO Incubator with HEPA M1271-0051 User’s Manual...
  • Page 13: Receiving And Inspection

    Supply nameplate data, including model number and serial number. The return authorization number must be plainly marked on any item(s) you return. Use the original shipping crate and packing materials for safe transport. New Brunswick Scientific User’s Manual...
  • Page 14 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 15: Graphic Symbols

    Indicates “Manual Adjustment”. Indicates “Percent Carbon Dioxide”. Indicates “Gas” (CO for this unit). Indicates “AC Power”. Indicates “Water Jacket Low”. Indicates “Protective Earth Ground”. Indicates “Relative Humidity”. Indicates “Percent Relative Humidity”. Indicates “Potential Shock Hazard” behind partition. New Brunswick Scientific User’s Manual...
  • Page 16 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 17: Installation

    Completely restrain each unit from tipping during lifting or transport. Remove all movable parts, such as shelves and trays. Lock the doors in the closed position during transfer to prevent shifting and damage. New Brunswick Scientific User’s Manual...
  • Page 18: Stacking

    Stacking Two CO28IR incubators may be stacked using the optional NBS stacking kit (PN M1271-9990). See the procedure outlined in Figure 1. These units are heavy, so care should be taken to use appropriate lifting devices that are sufficiently rated for these loads.
  • Page 19: Cleaning

    Always disconnect the unit from the electrical service when cleaning and assure all volatile or flammable cleaners are evaporated and dry before reattaching the unit to the power supply. New Brunswick Scientific User’s Manual...
  • Page 20: Installing Shelves & Humidity Pan

    Place the humidity pan inside the incubator, in the center of the floor. See Figure 2a on the following page for a photograph of the shelves, fan cover, HEPA filter and humidity pan in place. CO28IR CO Incubators with HEPA M1271-0051...
  • Page 21: Installing Fan Cover & Hepa Filter

    Figure 2a: Shelves, Humidity Pan, Fan Cover & HEPA Filter Installed OUTER DOOR COVER INNER DOOR SHELF STANDARD HEPA FILTER SHELVES HUMIDITY PAN COPPER RING NOT INCLUDED New Brunswick Scientific User’s Manual...
  • Page 22 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 23: Controls

    The HIGH and LOW alarm indicators (red bars) will light whenever there is an alarm condition associated with the temperature within the chamber. The MUTE indicator (yellow bar) will light whenever the audible alarm has been deactivated..continued... New Brunswick Scientific User’s Manual...
  • Page 24: Door Temperature Control

    The Door Temperature controller (see Figure 4) is located on the outer door liner in the upper left corner. This control will maintain door temperature between 1º and 1.5ºC above the incubator chamber temperature to prevent condensation from forming on the glass door. CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 25: Power Cord Inlet

    HEPA CO Filter The CO28IR CO incubator design featurs a HEPA filtration system with a patented copper housing. As the chamber air is drawn through the filter system (see Figure 5), airborne microbes and isolated particulates are not only removed from the air, these contaminants are also destroyed through copper oxidation.
  • Page 26 The HEPA filter has an efficiency rating of 99.97% at 0.3 micrometer. The filter is easy to replace, requiring no tools (see Section 7.4 for replacement instructions). CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 27: Operation

    To adjust the setpoint on any of the controls: 1. Push and release either the UP or DOWN arrow key for the control you wish to set, and the digital display will start to blink from bright to dim. New Brunswick Scientific User’s Manual...
  • Page 28: Calibrating The Controls

    At least once a week, the water should be changed in the pan and the pan should be cleaned to help control contamination and to maintain proper surface tension. CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 29: Temperature Monitoring

    1. After the incubator has been running for 24 hours and the temperature display is stable at the setpoint, read the temperature in the chamber from the reference thermometer and, if necessary, recalibrate the display using the instructions in Section 5.4. New Brunswick Scientific User’s Manual...
  • Page 30: Co 2 Supply System & Control System

    Prior to any attempt to hook up or run the CO control system, the water jacket must be filled (see Section 5.2) and the temperature must be adjusted. Figure 6: Fittings, Ports & Valves (schematic, top view) REAR PANEL FRONT PANEL CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 31 CAUTION Use only medical grade CO in your incubator. Only medical grade CO should be used in your incubator. The use of any lower quality CO may damage your incubator and void your warranty. New Brunswick Scientific User’s Manual...
  • Page 32: Setting The Co 2 Control

    Fyrite use is done. 5.12 Alarms The temperature control and the CO control are both equipped with visual and audible alarms, as explained below. CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 33: Draining The Water Jacket

    To drain the unit, hook a suitable hose to the siphon tube located to the left of the fill port mentioned above, start a siphon and allow the unit to empty into a suitable service drain or container. New Brunswick Scientific User’s Manual...
  • Page 34 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 35: Fyrite Co Checking

    7. Tip the canister to the 45º position to ensure all fluid has been released from the top of the canister. 8. Read CO concentration in %. 9. Repeat all of these steps two more times to ensure constant readings. New Brunswick Scientific User’s Manual...
  • Page 36 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 37: Maintenance

    4. Clean the humidity pan and replenish its water on a weekly basis. Fill the stainless steel humidity pan with distilled water only. Maintenance Replenish water in the water jacket as needed. Check CO supply periodically; don’t let it run out. The internal auto tank switch is not alarmed. New Brunswick Scientific User’s Manual...
  • Page 38: Replacing The Internal Co 2 Filter

    The HEPA filter is easily removed and replaced, with no need for tools. The filter snaps into a fixed coupling ring, mounted on the fan cover inside the incubator (see Figure 7 on the following page). CO28IR CO Incubators with HEPA M1271-0051...
  • Page 39: Storage

    Completely restrain each unit from tipping during lifting or transport. Remove all movable parts, such as shelves and trays. Lock the doors in the closed position during transfer to prevent shifting and damage. New Brunswick Scientific User’s Manual...
  • Page 40 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 41: Troubleshooting

    Safety is operating correctly. 8. Wiring problem: check all functions and compare wiring to schematics in Section 11, especially around any areas recently worked on. 9. Loose connection: check electronics compartment for loose connections..continued... New Brunswick Scientific User’s Manual...
  • Page 42 5.8 for correct setting. 7. Electrical noise: remove nearby sources of RFI including motors, arcing relays or radio transmitters..continued... CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 43 Customer Service the part number on the controller chip to confirm. 6. Input pressure too high: should not exceed 20 psi. 7. CO sensor partially plugged with dirt or condensation..continued... New Brunswick Scientific User’s Manual...
  • Page 44 Display and Fyrite reading do not match 1. Calibration error: clear chamber for 12 hours and confirm at "0" 2. Turn setpoint up and down to see if solenoid works by feeling and listening to valve..continued... CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 45 2. Check output signal from controller. 3. Check solenoid valve for correct operation. 4. Leak in plumbing, including between regulator and CO tank. 5. Door being opened too often..continued... New Brunswick Scientific User’s Manual...
  • Page 46 MECHANICAL CONTROL Motor doesn't move 1. If shaft spins freely: check connections to motor and check voltage to motor. 2. If shaft rubs or is frozen, relieve binding and retest..continued... CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 47 4. Check all wiring connections, especially around the On/Off switch. Low level light does not operate correctly Water needs to be very close to top to activate switch: hand fill to top to confirm switch has been moved..continued... New Brunswick Scientific User’s Manual...
  • Page 48 The incubator is designed so that no internal electrical servicing should be required under normal conditions. Should electrical servicing become necessary, it should be performed by qualified service personnel. CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 49: Parts List

    Power Inlet Fuse P0647-0110 P0647-0111 Power Inlet P0647-0180 P0647-0180 Power Switch P0647-0190 P0647-0190 Solenoid Valve P0647-0200 P0647-0201 Temperature Control w/Alarm P0647-0210 P0647-0211 Water Level Switch P0647-0220 P0647-0220 OPTIONAL Stacking Kit (for 2 units) M1271-9990 M1271-9990 New Brunswick Scientific User’s Manual...
  • Page 50 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 51: Unit Specifications

    Uniformity ± 0.1º @ 37º C ± 0.05º C Sensitivity * with fan cover panel in place, the interior height is 25.8 inches / 65.5 cm (excluding the HEPA filter) ** WJ = Water jacket New Brunswick Scientific User’s Manual...
  • Page 52 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 53: Wiring Diagrams

    Figure 8: Auxiliary Systems Schematic (120V) AUXILIARY SYSTEMS SCHEMATIC (120V) New Brunswick Scientific User’s Manual...
  • Page 54: Temperature Control Schematic (120V)

    Figure 9: Temperature Control Schematic (120V) TEMPERATURE CONTROL SCHEMATIC (120V) CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 55: Humidity Control Schematic (120V)

    Figure 10: CO & Humidity Control Schematic (120V) & HUMIDITY CONTROL SCHEMATIC (120V) New Brunswick Scientific User’s Manual...
  • Page 56 Figure 11: Auxiliary Systems Schematic (230V) AUXILIARY SYSTEMS SCHEMATIC (230V) CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 57: Temperature Control Schematic (230V)

    Figure 12: Temperture Control Schematic (230V) TEMPERATURE CONTROL SCHEMATIC (230V) New Brunswick Scientific User’s Manual...
  • Page 58: Co 2 & Humidity Control Schematic (230V)

    Figure 13: CO2 & Humidity Control Schematic (230V) & HUMIDITY CONTROL SCHEMATIC (230V) CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 59: List Of Tables

    Temperature Control Schematic (120V) & Humidity Control Schematic (120V) Auxiliary System Schematic (230V) Temperature Control Schematic (230V) & Humidity Control Schematic (230V) 11.2 List of Tables Table Description Page Control Panel Symbols Control Panel Features New Brunswick Scientific User’s Manual...
  • Page 60 THIS PAGE IS INTENTIONALLY BLANK CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...
  • Page 61: Index

    Manual Conventions ............. vii Door Temperature Controller ......12, 13, 17 Measuring CO Concentration ........23 Draining the Water Jacket..........21 Medical Grade CO ............19 Drawing Index ...............47 NOTE Electrical Supply..............5 Symbol for ..............vii Exterior Dimensions ............39 New Brunswick Scientific User’s Manual...
  • Page 62 Filling the ..............15 & Humidity Control (120V) .......43 Water Jacket & Humidity Control (230V) .......46 Draining the ............... 21 Temperature Control (120V)........42 Water Jacket Low............ 12, 15 Temperature Control (230V)........45 Weight................39 Shelving CO28IR CO Incubators with HEPA M1271-0051 User’s Manual...