AES 7007 Security Subscriber
4.
Completed holes will appear as shown in the figure below.
5.
Push switch mounting screws from the rear of the enclosure through each small drilled hole.
6.
Place the plunger switch on the mounting screws inside the enclosure with the plunger pin extending out of the
back of the enclosure. Fasten the switch in place with supplied nuts.
7.
Adjust the plunger switch length to ensure contact when the enclosure is pressed against the mounting surface.
8.
Wire the switch to the required zone input on the Model 7007 mainboard.
9.
When subscriber enclosure is mounted and powered up, configure the enclosure tamper zone input.
.