Interface Connectors

The following are the Adit 3104 interface connectors:
Front of Adit
(1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.
(1) 10/100Base-T WAN port (RJ-45)
(4) 10/100Base-T switched LAN ports (RJ-45)
Tip and Ring Analog Interface equipped with standard 25-pair Telco Connector
Back of Adit
RS-232 craft port connector for local management
Power input connector
Ground connector

Grounding the Unit

WARNING!
PROTECTION OF USERS AND SERVICE PERSONNEL
Chassis ground is located on the back of the unit.
To ground the unit:
1. Connect a minimum 14 AWG ground
wire with a #8 ring tongue terminal (not
included) to the chassis ground on the
back of the unit. Secure with the 8-32
screw and lock washer provided.
2. Connect the opposite end of the ground
wire to a suitable earth grounding point
such as a building grounding electrode,
metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.
Adit 3104 - Release 1.6
T
A
3104
HE
DIT
ARE REQUIRED TO BE PERMANENTLY GROUNDED FOR THE
Electrical Installation & Cabling
.
Chassis
Ground
Interface Connectors
3-3