IMPORTANT NOTICE Brinsea Products Ltd and its agents or distributors will not be responsible for loss of animals in the event of failure however caused and the user is advised to arrange his own insurance cover where loss of power or...
1-888-667-7009. Go to www.Brinsea.com and register as a free member of the Brinsea Email Group to receive the latest news and information such as advance notice about new products, special offers, exclusive competitions and much more.
HD4001 US Issue 01 MAIN MENU – QUICK REFERENCE PRESS BOTH BUTTONS TO UNLOCK THE MAIN MENU SELECT THE OPTION / RETURN TO THE MENU. GO FORWARD ONE SCREEN / INCREASE THE VALUE / DISPLAY IN CELSIUS. GO BACK ONE SCREEN / DECREASE THE VALUE / DISPLAY IN FAHRENHEIT. 30.0C TEMP TEMPERATURE.
7mm / 8mm wrench Please identify each part and check that they are all present and undamaged. If there are any parts damaged or missing please contact your retailer or Brinsea Products (at the address at the end of the document).
HD4001 US Issue 01 4 Location and Assembly Your brooder/ICU will give best results in a room free from wide temperature variations and with generous ventilation – particularly if several incubators / brooders are running at the same time. Ensure that the room temperature cannot drop on a cold night.
Page 6
HD4001 US Issue 01 If caring for small animals with long claws such as hedgehogs, the door edge strip may be fitted as shown to ensure claws cannot pass through any door gap: Loosen the top hinge/cabinet Loosen the bottom Slide the door as far as it will fixing.
HD4001 US Issue 01 Your brooder/ICU is supplied with air filter media fitted at the air inlet (see fig 1) and at each end of the heater enclosure (see picture 9 above). For details of filter replacement see the Servicing section. Place the brooder/ICU on a scratch and moisture resistant surface.
Page 8
HD4001 US Issue 01 HIGH INCUBATION TEMPERATURE ALARM DISPLAY – If the measured temperature goes up by more than the figure in the ALARM HI screen, the alarm will sound immediately and “H” will be displayed. Press OK to silence the alarm for 30 minutes. If the high temperature problem rectifies itself the “H”...
HD4001 US Issue 01 CHANGING SETTINGS – The Main Menu allows the various settings to be modified and saved. All changes are retained in the event of a power cut. To access the Main Menu, press the + and – buttons simultaneously to unlock the display. For full details of menu settings please refer to the guide on page 3.
HD4001 US Issue 01 Temperatures too high can cause heat stress, dehydration, deformities or haemorrhaging under the skin. Low temperature may reduce appetite and retard growth. Observation of the bird is the best guide to its comfort. Chicks try to huddle together if cold and move about seeking parental warmth. Chicks too warm separate and pant.
HD4001 US Issue 01 Small Animal Care 9. 1 Your TLC has been specifically designed for the care of injured or sick small animals. Animals should always be cared for following the instructions and advice given by your veterinary surgeon. 9.
4 for assembly guide. The cabinet base and the door may be wet-cleaned with mild detergent and then disinfected with water-based disinfectant solution. 10.5 Replacement filters and evaporating blocks are available from Brinsea Products at the address at the end of this document or from your Brinsea agent. 11 Servicing and Calibration 11.1...
Page 13
Replace with a fuse of the same type and rating if necessary (20mm, 2A, Time delay, 250V). 11.7 If the problem persists contact your distributor or Brinsea Products Service Dept. 11.8 The digital temperature display is individually calibrated during manufacture but may be re-calibrated if required.
Need help?
Do you have a question about the TLC-40 Eco II Series and is the answer not in the manual?
Questions and answers